tools/power turbostat: Use standard Energy Unit for SPR Dram RAPL domain

Intel Xeon servers used to use a fixed energy resolution (15.3uj) for
Dram RAPL domain. But on SPR, Dram RAPL domain follows the standard
energy resolution as described in MSR_RAPL_POWER_UNIT.

Remove the SPR rapl_dram_energy_units quirk.

Fixes: e7af1ed3fa ("tools/power turbostat: Support additional CPU model numbers")
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
Tested-by: Wang Wendy <wendy.wang@intel.com>
Signed-off-by: Len Brown <len.brown@intel.com>
This commit is contained in:
Zhang Rui 2022-09-24 13:47:38 +08:00 committed by Len Brown
parent 3ea8e52ec9
commit b2d433ae63

View File

@ -4567,7 +4567,6 @@ static double rapl_dram_energy_units_probe(int model, double rapl_energy_units)
case INTEL_FAM6_SKYLAKE_X: /* SKX */
case INTEL_FAM6_XEON_PHI_KNL: /* KNL */
case INTEL_FAM6_ICELAKE_X: /* ICX */
case INTEL_FAM6_SAPPHIRERAPIDS_X: /* SPR */
return (rapl_dram_energy_units = 15.3 / 1000000);
default:
return (rapl_energy_units);