power: supply: bq24190: Call power_supply_changed() after updating input current
[ Upstream commit 77c2a3097d7029441e8a91aa0de1b4e5464593da ] The bq24192 model relies on external charger-type detection and once that is done the bq24190_charger code will update the input current. In this case, when the initial power_supply_changed() call is made from the interrupt handler, the input settings are 5V/0.5A which on many devices is not enough power to charge (while the device is on). On many devices the fuel-gauge relies in its external_power_changed callback to timely signal userspace about charging <-> discharging status changes. Add a power_supply_changed() call after updating the input current. This allows the fuel-gauge driver to timely recheck if the battery is charging after the new input current has been applied and then it can immediately notify userspace about this. Fixes: 18f8e6f695ac ("power: supply: bq24190_charger: Get input_current_limit from our supplier") Signed-off-by: Hans de Goede <hdegoede@redhat.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com> Signed-off-by: Sasha Levin <sashal@kernel.org>
This commit is contained in:
parent
224f7bbf57
commit
b557220d31
@ -1215,6 +1215,7 @@ static void bq24190_input_current_limit_work(struct work_struct *work)
|
||||
bq24190_charger_set_property(bdi->charger,
|
||||
POWER_SUPPLY_PROP_INPUT_CURRENT_LIMIT,
|
||||
&val);
|
||||
power_supply_changed(bdi->charger);
|
||||
}
|
||||
|
||||
/* Sync the input-current-limit with our parent supply (if we have one) */
|
||||
|
Loading…