HID: hid-input: occasionally report stylus battery even if not changed
There are styluses that only report their battery status when they are touching the touchscreen; additionally we currently suppress battery reports if capacity has not changed. To help userspace recognize how long ago the device reported battery status, let's send the change event through if either capacity has changed, or at least 30 seconds have passed since last report we've let through. Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
committed by
Jiri Kosina
parent
bf36c6b946
commit
c6838eeef2
@@ -534,9 +534,12 @@ static void hidinput_update_battery(struct hid_device *dev, int value)
|
||||
capacity = hidinput_scale_battery_capacity(dev, value);
|
||||
|
||||
if (dev->battery_status != HID_BATTERY_REPORTED ||
|
||||
capacity != dev->battery_capacity) {
|
||||
capacity != dev->battery_capacity ||
|
||||
ktime_after(ktime_get_coarse(), dev->battery_ratelimit_time)) {
|
||||
dev->battery_capacity = capacity;
|
||||
dev->battery_status = HID_BATTERY_REPORTED;
|
||||
dev->battery_ratelimit_time =
|
||||
ktime_add_ms(ktime_get_coarse(), 30 * 1000);
|
||||
power_supply_changed(dev->battery);
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user