iio: temperature: mcp9600: Fix temperature reading for negative values
commit 827dca3129708a8465bde90c86c2e3c38e62dd4f upstream. Temperature is stored as 16bit value in two's complement format. Current implementation ignores the sign bit. Make it aware of the sign bit by using sign_extend32. Fixes: 3f6b9598b6df ("iio: temperature: Add MCP9600 thermocouple EMF converter") Signed-off-by: Dimitri Fedrau <dima.fedrau@gmail.com> Reviewed-by: Marcelo Schmitt <marcelo.schmitt1@gmail.com> Tested-by: Andrew Hepp <andrew.hepp@ahepp.dev> Link: https://lore.kernel.org/r/20240424185913.1177127-1-dima.fedrau@gmail.com Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
6f0cfe3b8d
commit
c70cc82c80
@ -52,7 +52,8 @@ static int mcp9600_read(struct mcp9600_data *data,
|
||||
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
*val = ret;
|
||||
|
||||
*val = sign_extend32(ret, 15);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|