hwmon: (lm90) Do not report 'busy' status bit as alarm
Bit 7 of the status register indicates that the chip is busy doing a conversion. It does not indicate an alarm status. Stop reporting it as alarm status bit. Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
parent
da7dc05684
commit
cdc5287aca
@ -200,6 +200,7 @@ enum chips { lm90, adm1032, lm99, lm86, max6657, max6659, adt7461, max6680,
|
|||||||
#define LM90_STATUS_RHIGH (1 << 4) /* remote high temp limit tripped */
|
#define LM90_STATUS_RHIGH (1 << 4) /* remote high temp limit tripped */
|
||||||
#define LM90_STATUS_LLOW (1 << 5) /* local low temp limit tripped */
|
#define LM90_STATUS_LLOW (1 << 5) /* local low temp limit tripped */
|
||||||
#define LM90_STATUS_LHIGH (1 << 6) /* local high temp limit tripped */
|
#define LM90_STATUS_LHIGH (1 << 6) /* local high temp limit tripped */
|
||||||
|
#define LM90_STATUS_BUSY (1 << 7) /* conversion is ongoing */
|
||||||
|
|
||||||
#define MAX6696_STATUS2_R2THRM (1 << 1) /* remote2 THERM limit tripped */
|
#define MAX6696_STATUS2_R2THRM (1 << 1) /* remote2 THERM limit tripped */
|
||||||
#define MAX6696_STATUS2_R2OPEN (1 << 2) /* remote2 is an open circuit */
|
#define MAX6696_STATUS2_R2OPEN (1 << 2) /* remote2 is an open circuit */
|
||||||
@ -820,7 +821,7 @@ static int lm90_update_device(struct device *dev)
|
|||||||
val = lm90_read_reg(client, LM90_REG_R_STATUS);
|
val = lm90_read_reg(client, LM90_REG_R_STATUS);
|
||||||
if (val < 0)
|
if (val < 0)
|
||||||
return val;
|
return val;
|
||||||
data->alarms = val; /* lower 8 bit of alarms */
|
data->alarms = val & ~LM90_STATUS_BUSY;
|
||||||
|
|
||||||
if (data->kind == max6696) {
|
if (data->kind == max6696) {
|
||||||
val = lm90_select_remote_channel(data, 1);
|
val = lm90_select_remote_channel(data, 1);
|
||||||
|
Loading…