net: hns: Fix wrong read accesses via Clause 45 MDIO protocol
When reading phy registers via Clause 45 MDIO protocol, after write address operation, the driver use another write address operation, so can not read the right value of any phy registers. This patch fixes it. Signed-off-by: Yonglong Liu <liuyonglong@huawei.com> Signed-off-by: Peng Li <lipeng321@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
ed29ca8b95
commit
cec8abba13
@ -321,7 +321,7 @@ static int hns_mdio_read(struct mii_bus *bus, int phy_id, int regnum)
|
||||
}
|
||||
|
||||
hns_mdio_cmd_write(mdio_dev, is_c45,
|
||||
MDIO_C45_WRITE_ADDR, phy_id, devad);
|
||||
MDIO_C45_READ, phy_id, devad);
|
||||
}
|
||||
|
||||
/* Step 5: waitting for MDIO_COMMAND_REG 's mdio_start==0,*/
|
||||
|