dt-bindings: iio: afe: add bindings for temperature-sense-rtd
An ADC is often used to measure other quantities indirectly. This binding describe one case, the measurement of a temperature through the voltage across an RTD resistor such as a PT1000. Signed-off-by: Liam Beguin <liambeguin@gmail.com> Reviewed-by: Rob Herring <robh@kernel.org> Reviewed-by: Peter Rosin <peda@axentia.se> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Link: https://lore.kernel.org/r/20220213025739.2561834-10-liambeguin@gmail.com Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
03e7d21ee1
commit
d065a283fe
@ -0,0 +1,101 @@
|
||||
# SPDX-License-Identifier: (GPL-2.0 OR BSD-2-Clause)
|
||||
%YAML 1.2
|
||||
---
|
||||
$id: http://devicetree.org/schemas/iio/afe/temperature-sense-rtd.yaml#
|
||||
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
||||
|
||||
title: Temperature Sense RTD
|
||||
|
||||
maintainers:
|
||||
- Liam Beguin <liambeguin@gmail.com>
|
||||
|
||||
description: |
|
||||
RTDs (Resistance Temperature Detectors) are a kind of temperature sensors
|
||||
used to get a linear voltage to temperature reading within a give range
|
||||
(usually 0 to 100 degrees Celsius).
|
||||
|
||||
When an io-channel measures the output voltage across an RTD such as a
|
||||
PT1000, the interesting measurement is almost always the corresponding
|
||||
temperature, not the voltage output. This binding describes such a circuit.
|
||||
|
||||
The general transfer function here is (using SI units)
|
||||
|
||||
V = R(T) * iexc
|
||||
R(T) = r0 * (1 + alpha * T)
|
||||
T = 1 / (alpha * r0 * iexc) * (V - r0 * iexc)
|
||||
|
||||
The following circuit matches what's in the examples section.
|
||||
|
||||
5V0
|
||||
-----
|
||||
|
|
||||
+---+----+
|
||||
| R 5k |
|
||||
+---+----+
|
||||
|
|
||||
V 1mA
|
||||
|
|
||||
+---- Vout
|
||||
|
|
||||
+---+----+
|
||||
| PT1000 |
|
||||
+---+----+
|
||||
|
|
||||
-----
|
||||
GND
|
||||
|
||||
properties:
|
||||
compatible:
|
||||
const: temperature-sense-rtd
|
||||
|
||||
io-channels:
|
||||
maxItems: 1
|
||||
description: |
|
||||
Channel node of a voltage io-channel.
|
||||
|
||||
'#io-channel-cells':
|
||||
const: 0
|
||||
|
||||
excitation-current-microamp:
|
||||
description: The current fed through the RTD sensor.
|
||||
|
||||
alpha-ppm-per-celsius:
|
||||
description: |
|
||||
alpha can also be expressed in micro-ohms per ohm Celsius. It's a linear
|
||||
approximation of the resistance versus temperature relationship
|
||||
between 0 and 100 degrees Celsius.
|
||||
|
||||
alpha = (R_100 - R_0) / (100 * R_0)
|
||||
|
||||
Where, R_100 is the resistance of the sensor at 100 degrees Celsius, and
|
||||
R_0 (or r-naught-ohms) is the resistance of the sensor at 0 degrees
|
||||
Celsius.
|
||||
|
||||
Pure platinum has an alpha of 3925. Industry standards such as IEC60751
|
||||
and ASTM E-1137 specify an alpha of 3850.
|
||||
|
||||
r-naught-ohms:
|
||||
description: |
|
||||
Resistance of the sensor at 0 degrees Celsius.
|
||||
Common values are 100 for PT100, 500 for PT500, and 1000 for PT1000
|
||||
|
||||
additionalProperties: false
|
||||
required:
|
||||
- compatible
|
||||
- io-channels
|
||||
- excitation-current-microamp
|
||||
- alpha-ppm-per-celsius
|
||||
- r-naught-ohms
|
||||
|
||||
examples:
|
||||
- |
|
||||
pt1000_1: temperature-sensor0 {
|
||||
compatible = "temperature-sense-rtd";
|
||||
#io-channel-cells = <0>;
|
||||
io-channels = <&temp_adc1 0>;
|
||||
|
||||
excitation-current-microamp = <1000>; /* i = U/R = 5 / 5000 */
|
||||
alpha-ppm-per-celsius = <3908>;
|
||||
r-naught-ohms = <1000>;
|
||||
};
|
||||
...
|
Loading…