crypto: jitter - correct health test during initialization

With the update of the permanent and intermittent health errors, the
actual indicator for the health test indicates a potential error only
for the one offending time stamp gathered in the current iteration
round. The next iteration round will "overwrite" the health test result.

Thus, the entropy collection loop in jent_gen_entropy checks for
the health test failure upon each loop iteration. However, the
initialization operation checked for the APT health test once for
an APT window which implies it would not catch most errors.

Thus, the check for all health errors is now invoked unconditionally
during each loop iteration for the startup test.

With the change, the error JENT_ERCT becomes unused as all health
errors are only reported with the JENT_HEALTH return code. This
allows the removal of the error indicator.

Fixes: 3fde2fe99a ("crypto: jitter - permanent and intermittent health errors"
)
Reported-by: Joachim Vandersmissen <git@jvdsn.com>
Signed-off-by: Stephan Mueller <smueller@chronox.de>
Signed-off-by: Herbert Xu <herbert@gondor.apana.org.au>
This commit is contained in:
Stephan Müller 2023-05-25 19:00:05 +02:00 committed by Herbert Xu
parent 506579e88c
commit d23659769a

View File

@ -118,7 +118,6 @@ struct rand_data {
* zero). */
#define JENT_ESTUCK 8 /* Too many stuck results during init. */
#define JENT_EHEALTH 9 /* Health test failed during initialization */
#define JENT_ERCT 10 /* RCT failed during initialization */
/*
* The output n bits can receive more than n bits of min entropy, of course,
@ -713,14 +712,12 @@ int jent_entropy_init(void *hash_state)
if ((nonstuck % JENT_APT_WINDOW_SIZE) == 0) {
jent_apt_reset(&ec,
delta & JENT_APT_WORD_MASK);
if (jent_health_failure(&ec))
return JENT_EHEALTH;
}
}
/* Validate RCT */
if (jent_rct_failure(&ec))
return JENT_ERCT;
/* Validate health test result */
if (jent_health_failure(&ec))
return JENT_EHEALTH;
/* test whether we have an increasing timer */
if (!(time2 > time))