iio: pressure: bmp280: remove unused options from device tree documentation

There are several options in the device tree documentation that are
no longer relevant for the current in-kernel bmp280 driver so this patch
removes them.

Signed-off-by: Brian Masney <masneyb@onstation.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Brian Masney 2018-07-10 21:33:45 -04:00 committed by Jonathan Cameron
parent de8df0b9c3
commit d2b863baf1

View File

@ -8,10 +8,6 @@ Required properties:
"bosch,bme280"
Optional properties:
- chip-id: configurable chip id for non-default chip revisions
- temp-measurement-period: temperature measurement period (milliseconds)
- default-oversampling: default oversampling value to be used at startup,
value range is 0-3 with rising sensitivity.
- interrupt-parent: should be the phandle for the interrupt controller
- interrupts: interrupt mapping for IRQ
- reset-gpios: a GPIO line handling reset of the sensor: as the line is
@ -24,9 +20,6 @@ Example:
pressure@77 {
compatible = "bosch,bmp085";
reg = <0x77>;
chip-id = <10>;
temp-measurement-period = <100>;
default-oversampling = <2>;
interrupt-parent = <&gpio0>;
interrupts = <25 IRQ_TYPE_EDGE_RISING>;
reset-gpios = <&gpio0 26 GPIO_ACTIVE_LOW>;

Before

Width:  |  Height:  |  Size: 1.1 KiB

After

Width:  |  Height:  |  Size: 816 B