bnx2x: use the right constant

[ Upstream commit dd612f18a49b63af8b3a5f572d999bdb197385bc ]

Nearby code that also tests port suggests that the P0 constant should be
used when port is zero.

The semantic match that finds this problem is as follows:
(http://coccinelle.lip6.fr/)

// <smpl>
@@
expression e,e1;
@@

* e ? e1 : e1
// </smpl>

Fixes: 6c3218c6f7e5 ("bnx2x: Adjust ETS to 578xx")
Signed-off-by: Julia Lawall <Julia.Lawall@lip6.fr>
Signed-off-by: David S. Miller <davem@davemloft.net>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Julia Lawall 2018-06-06 15:03:22 +02:00 committed by Greg Kroah-Hartman
parent 128f0d7005
commit d591263c79

View File

@ -588,7 +588,7 @@ static void bnx2x_ets_e3b0_nig_disabled(const struct link_params *params,
* slots for the highest priority.
*/
REG_WR(bp, (port) ? NIG_REG_P1_TX_ARB_NUM_STRICT_ARB_SLOTS :
NIG_REG_P1_TX_ARB_NUM_STRICT_ARB_SLOTS, 0x100);
NIG_REG_P0_TX_ARB_NUM_STRICT_ARB_SLOTS, 0x100);
/* Mapping between the CREDIT_WEIGHT registers and actual client
* numbers
*/