iio: documentation: Document scd4x calibration use
Add entries from Documentation/ABI/testing/sysfs-bus-iio-scd30 to Documentation/ABI/testing/sysfs-bus-iio. The attributes of the scd4x and scd30 are common. Remove Documentation/ABI/testing/sysfs-bus-iio-scd30. Signed-off-by: Roan van Dijk <roan@protonic.nl> Link: https://lore.kernel.org/r/20211008101706.755942-5-roan@protonic.nl Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
49d22b695c
commit
d6fa140630
@ -1958,3 +1958,44 @@ Description:
|
||||
Specify the percent for light sensor relative to the channel
|
||||
absolute value that a data field should change before an event
|
||||
is generated. Units are a percentage of the prior reading.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/calibration_auto_enable
|
||||
Date: June 2020
|
||||
KernelVersion: 5.8
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Some sensors have the ability to apply auto calibration at
|
||||
runtime. For example, it may be necessary to compensate for
|
||||
contaminant build-up in a measurement chamber or optical
|
||||
element deterioration that would otherwise lead to sensor drift.
|
||||
|
||||
Writing 1 or 0 to this attribute will respectively activate or
|
||||
deactivate this auto calibration function.
|
||||
|
||||
Upon reading, the current status is returned.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/calibration_forced_value
|
||||
Date: June 2020
|
||||
KernelVersion: 5.8
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Some sensors have the ability to apply a manual calibration using
|
||||
a known measurement value, perhaps obtained from an external
|
||||
reference device.
|
||||
|
||||
Writing a value to this function will force such a calibration
|
||||
change. For the scd30 the value should be from the range
|
||||
[400 1 2000].
|
||||
|
||||
Note for the scd30 that a valid value may only be obtained once
|
||||
it is has been written. Until then any read back of this value
|
||||
should be ignored. As for the scd4x an error will be returned
|
||||
immediately if the manual calibration has failed.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/calibration_forced_value_available
|
||||
KernelVersion: 5.15
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Available range for the forced calibration value, expressed as:
|
||||
|
||||
- a range specified as "[min step max]"
|
||||
|
@ -1,34 +0,0 @@
|
||||
What: /sys/bus/iio/devices/iio:deviceX/calibration_auto_enable
|
||||
Date: June 2020
|
||||
KernelVersion: 5.8
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Contaminants build-up in the measurement chamber or optical
|
||||
elements deterioration leads to sensor drift.
|
||||
|
||||
One can compensate for sensor drift by using automatic self
|
||||
calibration procedure (asc).
|
||||
|
||||
Writing 1 or 0 to this attribute will respectively activate or
|
||||
deactivate asc.
|
||||
|
||||
Upon reading current asc status is returned.
|
||||
|
||||
What: /sys/bus/iio/devices/iio:deviceX/calibration_forced_value
|
||||
Date: June 2020
|
||||
KernelVersion: 5.8
|
||||
Contact: linux-iio@vger.kernel.org
|
||||
Description:
|
||||
Contaminants build-up in the measurement chamber or optical
|
||||
elements deterioration leads to sensor drift.
|
||||
|
||||
One can compensate for sensor drift by using forced
|
||||
recalibration (frc). This is useful in case there's known
|
||||
co2 reference available nearby the sensor.
|
||||
|
||||
Picking value from the range [400 1 2000] and writing it to the
|
||||
sensor will set frc.
|
||||
|
||||
Upon reading current frc value is returned. Note that after
|
||||
power cycling default value (i.e 400) is returned even though
|
||||
internally sensor had recalibrated itself.
|