regulator: Ensure val is initialised in 88pm8607 choose_voltage()
If we fall through it means that we hit an unknown regulator/chip combination so set -ENOENT as an explicit flag (the return code is only used internally). Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This commit is contained in:
parent
9992ef40ff
commit
ddec68107a
@ -170,7 +170,8 @@ static int choose_voltage(struct regulator_dev *rdev, int min_uV, int max_uV)
|
||||
{
|
||||
struct pm8607_regulator_info *info = rdev_get_drvdata(rdev);
|
||||
uint8_t chip_id = info->chip->chip_id;
|
||||
int val, ret;
|
||||
int val = -ENOENT;
|
||||
int ret;
|
||||
|
||||
switch (info->desc.id) {
|
||||
case PM8607_ID_BUCK1:
|
||||
|
Loading…