dt-bindings: timer: nuvoton: Clarify that interrupt of timer 0 should be specified
The NPCM750 Timer/Watchdog Controller has multiple interrupt lines, connected to multiple timers. The driver uses timer 0 for timer interrupts, so the interrupt line corresponding to timer 0 should be specified in DT. I removed the mention of "flags for falling edge", because the timer controller uses high-level interrupts rather than falling-edge interrupts, and whether flags should be specified is up the interrupt controller's DT binding. Signed-off-by: Jonathan Neuschäfer <j.neuschaefer@gmx.net> Acked-by: Rob Herring <robh@kernel.org> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> Link: https://lore.kernel.org/r/20210108163004.492649-1-j.neuschaefer@gmx.net
This commit is contained in:
parent
98509310e4
commit
e1922b5da0
@ -6,8 +6,7 @@ timer counters.
|
||||
Required properties:
|
||||
- compatible : "nuvoton,npcm750-timer" for Poleg NPCM750.
|
||||
- reg : Offset and length of the register set for the device.
|
||||
- interrupts : Contain the timer interrupt with flags for
|
||||
falling edge.
|
||||
- interrupts : Contain the timer interrupt of timer 0.
|
||||
- clocks : phandle of timer reference clock (usually a 25 MHz clock).
|
||||
|
||||
Example:
|
||||
|