dt-bindings: net: dp83826: support TX data voltage tuning
Add properties ti,cfg-dac-minus-one-bp/ti,cfg-dac-plus-one-bp to support voltage tuning of logical levels -1/+1 of the MLT-3 encoded TX data. Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Signed-off-by: Catalin Popescu <catalin.popescu@leica-geosystems.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
7c754e6a6c
commit
ed1d7dac08
@ -62,6 +62,24 @@ properties:
|
||||
for the PHY. The internal delay for the PHY is fixed to 3.5ns relative
|
||||
to transmit data.
|
||||
|
||||
ti,cfg-dac-minus-one-bp:
|
||||
description: |
|
||||
DP83826 PHY only.
|
||||
Sets the voltage ratio (with respect to the nominal value)
|
||||
of the logical level -1 for the MLT-3 encoded TX data.
|
||||
enum: [5000, 5625, 6250, 6875, 7500, 8125, 8750, 9375, 10000,
|
||||
10625, 11250, 11875, 12500, 13125, 13750, 14375, 15000]
|
||||
default: 10000
|
||||
|
||||
ti,cfg-dac-plus-one-bp:
|
||||
description: |
|
||||
DP83826 PHY only.
|
||||
Sets the voltage ratio (with respect to the nominal value)
|
||||
of the logical level +1 for the MLT-3 encoded TX data.
|
||||
enum: [5000, 5625, 6250, 6875, 7500, 8125, 8750, 9375, 10000,
|
||||
10625, 11250, 11875, 12500, 13125, 13750, 14375, 15000]
|
||||
default: 10000
|
||||
|
||||
required:
|
||||
- reg
|
||||
|
||||
|