s390/cio: clear timer when terminating driver I/O
[ Upstream commit 410d5e13e7638bc146321671e223d56495fbf3c7 ] When we terminate driver I/O (because we need to stop using a certain channel path) we also need to ensure that a timer (which may have been set up using ccw_device_start_timeout) is cleared. Signed-off-by: Sebastian Ott <sebott@linux.vnet.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Sasha Levin <alexander.levin@microsoft.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
b912a541d4
commit
f18fb14521
@ -923,6 +923,7 @@ void ccw_device_kill_io(struct ccw_device *cdev)
|
||||
{
|
||||
int ret;
|
||||
|
||||
ccw_device_set_timeout(cdev, 0);
|
||||
cdev->private->iretry = 255;
|
||||
cdev->private->async_kill_io_rc = -EIO;
|
||||
ret = ccw_device_cancel_halt_clear(cdev);
|
||||
|