scsi: docs: convert scsi_fc_transport.txt to ReST
Link: https://lore.kernel.org/r/f75bd9b6512f223847cc4ece8bd7e8e72e434b21.1583136624.git.mchehab+huawei@kernel.org Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
parent
e513de9936
commit
fedd7a4d09
@ -33,5 +33,6 @@ Linux SCSI Subsystem
|
||||
qlogicfas
|
||||
scsi-changer
|
||||
scsi_eh
|
||||
scsi_fc_transport
|
||||
|
||||
scsi_transport_srp/figures
|
||||
|
@ -1,8 +1,13 @@
|
||||
SCSI FC Tansport
|
||||
=============================================
|
||||
.. SPDX-License-Identifier: GPL-2.0
|
||||
|
||||
================
|
||||
SCSI FC Tansport
|
||||
================
|
||||
|
||||
Date: 11/18/2008
|
||||
Kernel Revisions for features:
|
||||
|
||||
Kernel Revisions for features::
|
||||
|
||||
rports : <<TBS>>
|
||||
vports : 2.6.22
|
||||
bsg support : 2.6.30 (?TBD?)
|
||||
@ -12,25 +17,27 @@ Introduction
|
||||
============
|
||||
This file documents the features and components of the SCSI FC Transport.
|
||||
It also provides documents the API between the transport and FC LLDDs.
|
||||
The FC transport can be found at:
|
||||
|
||||
The FC transport can be found at::
|
||||
|
||||
drivers/scsi/scsi_transport_fc.c
|
||||
include/scsi/scsi_transport_fc.h
|
||||
include/scsi/scsi_netlink_fc.h
|
||||
include/scsi/scsi_bsg_fc.h
|
||||
|
||||
This file is found at Documentation/scsi/scsi_fc_transport.txt
|
||||
This file is found at Documentation/scsi/scsi_fc_transport.rst
|
||||
|
||||
|
||||
FC Remote Ports (rports)
|
||||
========================================================================
|
||||
========================
|
||||
<< To Be Supplied >>
|
||||
|
||||
|
||||
FC Virtual Ports (vports)
|
||||
========================================================================
|
||||
=========================
|
||||
|
||||
Overview:
|
||||
-------------------------------
|
||||
Overview
|
||||
--------
|
||||
|
||||
New FC standards have defined mechanisms which allows for a single physical
|
||||
port to appear on as multiple communication ports. Using the N_Port Id
|
||||
@ -61,12 +68,14 @@ Overview:
|
||||
Thus, whether a FC port is based on a physical port or on a virtual port,
|
||||
each will appear as a unique scsi_host with its own target and lun space.
|
||||
|
||||
Note: At this time, the transport is written to create only NPIV-based
|
||||
.. Note::
|
||||
At this time, the transport is written to create only NPIV-based
|
||||
vports. However, consideration was given to VF-based vports and it
|
||||
should be a minor change to add support if needed. The remaining
|
||||
discussion will concentrate on NPIV.
|
||||
|
||||
Note: World Wide Name assignment (and uniqueness guarantees) are left
|
||||
.. Note::
|
||||
World Wide Name assignment (and uniqueness guarantees) are left
|
||||
up to an administrative entity controlling the vport. For example,
|
||||
if vports are to be associated with virtual machines, a XEN mgmt
|
||||
utility would be responsible for creating wwpn/wwnn's for the vport,
|
||||
@ -91,18 +100,29 @@ Device Trees and Vport Objects:
|
||||
port's scsi_host.
|
||||
|
||||
Here's what to expect in the device tree :
|
||||
The typical Physical Port's Scsi_Host:
|
||||
|
||||
The typical Physical Port's Scsi_Host::
|
||||
|
||||
/sys/devices/.../host17/
|
||||
and it has the typical descendant tree:
|
||||
|
||||
and it has the typical descendant tree::
|
||||
|
||||
/sys/devices/.../host17/rport-17:0-0/target17:0:0/17:0:0:0:
|
||||
and then the vport is created on the Physical Port:
|
||||
|
||||
and then the vport is created on the Physical Port::
|
||||
|
||||
/sys/devices/.../host17/vport-17:0-0
|
||||
and the vport's Scsi_Host is then created:
|
||||
|
||||
and the vport's Scsi_Host is then created::
|
||||
|
||||
/sys/devices/.../host17/vport-17:0-0/host18
|
||||
and then the rest of the tree progresses, such as:
|
||||
|
||||
and then the rest of the tree progresses, such as::
|
||||
|
||||
/sys/devices/.../host17/vport-17:0-0/host18/rport-18:0-0/target18:0:0/18:0:0:0:
|
||||
|
||||
Here's what to expect in the sysfs tree :
|
||||
Here's what to expect in the sysfs tree::
|
||||
|
||||
scsi_hosts:
|
||||
/sys/class/scsi_host/host17 physical port's scsi_host
|
||||
/sys/class/scsi_host/host18 vport's scsi_host
|
||||
@ -116,8 +136,8 @@ Device Trees and Vport Objects:
|
||||
/sys/class/fc_remote_ports/rport-18:0-0 rport on the vport
|
||||
|
||||
|
||||
Vport Attributes:
|
||||
-------------------------------
|
||||
Vport Attributes
|
||||
----------------
|
||||
|
||||
The new fc_vport class object has the following attributes
|
||||
|
||||
@ -184,16 +204,18 @@ Vport Attributes:
|
||||
(e.g. 0x, x, etc).
|
||||
|
||||
|
||||
Vport States:
|
||||
-------------------------------
|
||||
Vport States
|
||||
------------
|
||||
|
||||
Vport instantiation consists of two parts:
|
||||
|
||||
- Creation with the kernel and LLDD. This means all transport and
|
||||
driver data structures are built up, and device objects created.
|
||||
This is equivalent to a driver "attach" on an adapter, which is
|
||||
independent of the adapter's link state.
|
||||
- Instantiation of the vport on the FC link via ELS traffic, etc.
|
||||
This is equivalent to a "link up" and successful link initialization.
|
||||
|
||||
Further information can be found in the interfaces section below for
|
||||
Vport Creation.
|
||||
|
||||
@ -227,6 +249,7 @@ Vport States:
|
||||
FC_VPORT_NO_FABRIC_SUPP - No Fabric Support
|
||||
The vport is not operational. One of the following conditions were
|
||||
encountered:
|
||||
|
||||
- The FC topology is not Point-to-Point
|
||||
- The FC port is not connected to an F_Port
|
||||
- The F_Port has indicated that NPIV is not supported.
|
||||
@ -251,32 +274,53 @@ Vport States:
|
||||
|
||||
The following state table indicates the different state transitions:
|
||||
|
||||
State Event New State
|
||||
--------------------------------------------------------------------
|
||||
n/a Initialization Unknown
|
||||
Unknown: Link Down Linkdown
|
||||
Link Up & Loop No Fabric Support
|
||||
Link Up & no Fabric No Fabric Support
|
||||
Link Up & FLOGI response No Fabric Support
|
||||
indicates no NPIV support
|
||||
Link Up & FDISC being sent Initializing
|
||||
Disable request Disable
|
||||
Linkdown: Link Up Unknown
|
||||
Initializing: FDISC ACC Active
|
||||
FDISC LS_RJT w/ no resources No Fabric Resources
|
||||
FDISC LS_RJT w/ invalid Fabric Rejected WWN
|
||||
pname or invalid nport_id
|
||||
FDISC LS_RJT failed for Vport Failed
|
||||
other reasons
|
||||
Link Down Linkdown
|
||||
Disable request Disable
|
||||
Disable: Enable request Unknown
|
||||
Active: LOGO received from fabric Fabric Logout
|
||||
Link Down Linkdown
|
||||
Disable request Disable
|
||||
Fabric Logout: Link still up Unknown
|
||||
+------------------+--------------------------------+---------------------+
|
||||
| State | Event | New State |
|
||||
+==================+================================+=====================+
|
||||
| n/a | Initialization | Unknown |
|
||||
+------------------+--------------------------------+---------------------+
|
||||
| Unknown: | Link Down | Linkdown |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Link Up & Loop | No Fabric Support |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Link Up & no Fabric | No Fabric Support |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Link Up & FLOGI response | No Fabric Support |
|
||||
| | indicates no NPIV support | |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Link Up & FDISC being sent | Initializing |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Disable request | Disable |
|
||||
+------------------+--------------------------------+---------------------+
|
||||
| Linkdown: | Link Up | Unknown |
|
||||
+------------------+--------------------------------+---------------------+
|
||||
| Initializing: | FDISC ACC | Active |
|
||||
| +--------------------------------+---------------------+
|
||||
| | FDISC LS_RJT w/ no resources | No Fabric Resources |
|
||||
| +--------------------------------+---------------------+
|
||||
| | FDISC LS_RJT w/ invalid | Fabric Rejected WWN |
|
||||
| | pname or invalid nport_id | |
|
||||
| +--------------------------------+---------------------+
|
||||
| | FDISC LS_RJT failed for | Vport Failed |
|
||||
| | other reasons | |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Link Down | Linkdown |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Disable request | Disable |
|
||||
+------------------+--------------------------------+---------------------+
|
||||
| Disable: | Enable request | Unknown |
|
||||
+------------------+--------------------------------+---------------------+
|
||||
| Active: | LOGO received from fabric | Fabric Logout |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Link Down | Linkdown |
|
||||
| +--------------------------------+---------------------+
|
||||
| | Disable request | Disable |
|
||||
+------------------+--------------------------------+---------------------+
|
||||
| Fabric Logout: | Link still up | Unknown |
|
||||
+------------------+--------------------------------+---------------------+
|
||||
|
||||
The following 4 error states all have the same transitions::
|
||||
|
||||
The following 4 error states all have the same transitions:
|
||||
No Fabric Support:
|
||||
No Fabric Resources:
|
||||
Fabric Rejected WWN:
|
||||
@ -285,8 +329,8 @@ Vport States:
|
||||
Link goes down Linkdown
|
||||
|
||||
|
||||
Transport <-> LLDD Interfaces :
|
||||
-------------------------------
|
||||
Transport <-> LLDD Interfaces
|
||||
-----------------------------
|
||||
|
||||
Vport support by LLDD:
|
||||
|
||||
@ -300,14 +344,17 @@ Vport support by LLDD:
|
||||
|
||||
Vport Creation:
|
||||
|
||||
The LLDD vport_create() syntax is:
|
||||
The LLDD vport_create() syntax is::
|
||||
|
||||
int vport_create(struct fc_vport *vport, bool disable)
|
||||
|
||||
where:
|
||||
vport: Is the newly allocated vport object
|
||||
disable: If "true", the vport is to be created in a disabled stated.
|
||||
where:
|
||||
|
||||
======= ===========================================================
|
||||
vport Is the newly allocated vport object
|
||||
disable If "true", the vport is to be created in a disabled stated.
|
||||
If "false", the vport is to be enabled upon creation.
|
||||
======= ===========================================================
|
||||
|
||||
When a request is made to create a new vport (via sgio/netlink, or the
|
||||
vport_create fc_host attribute), the transport will validate that the LLDD
|
||||
@ -317,6 +364,7 @@ Vport Creation:
|
||||
LLDD's vport_create() function with the newly allocated vport object.
|
||||
|
||||
As mentioned above, vport creation is divided into two parts:
|
||||
|
||||
- Creation with the kernel and LLDD. This means all transport and
|
||||
driver data structures are built up, and device objects created.
|
||||
This is equivalent to a driver "attach" on an adapter, which is
|
||||
@ -329,6 +377,7 @@ Vport Creation:
|
||||
infrastructure exists to support NPIV, and complete the first part of
|
||||
vport creation (data structure build up) before returning. We do not
|
||||
hinge vport_create() on the link-side operation mainly because:
|
||||
|
||||
- The link may be down. It is not a failure if it is. It simply
|
||||
means the vport is in an inoperable state until the link comes up.
|
||||
This is consistent with the link bouncing post vport creation.
|
||||
@ -337,11 +386,15 @@ Vport Creation:
|
||||
FC adapter. The vport_create is synonymous with driver attachment
|
||||
to the adapter, which is independent of link state.
|
||||
|
||||
Note: special error codes have been defined to delineate infrastructure
|
||||
.. Note::
|
||||
|
||||
special error codes have been defined to delineate infrastructure
|
||||
failure cases for quicker resolution.
|
||||
|
||||
The expected behavior for the LLDD's vport_create() function is:
|
||||
|
||||
- Validate Infrastructure:
|
||||
|
||||
- If the driver or adapter cannot support another vport, whether
|
||||
due to improper firmware, (a lie about) max_npiv, or a lack of
|
||||
some other resource - return VPCERR_UNSUPPORTED.
|
||||
@ -349,17 +402,21 @@ Vport Creation:
|
||||
the adapter and detects an overlap - return VPCERR_BAD_WWN.
|
||||
- If the driver detects the topology is loop, non-fabric, or the
|
||||
FLOGI did not support NPIV - return VPCERR_NO_FABRIC_SUPP.
|
||||
|
||||
- Allocate data structures. If errors are encountered, such as out
|
||||
of memory conditions, return the respective negative Exxx error code.
|
||||
- If the role is FCP Initiator, the LLDD is to :
|
||||
|
||||
- Call scsi_host_alloc() to allocate a scsi_host for the vport.
|
||||
- Call scsi_add_host(new_shost, &vport->dev) to start the scsi_host
|
||||
and bind it as a child of the vport device.
|
||||
- Initializes the fc_host attribute values.
|
||||
|
||||
- Kick of further vport state transitions based on the disable flag and
|
||||
link state - and return success (zero).
|
||||
|
||||
LLDD Implementers Notes:
|
||||
|
||||
- It is suggested that there be a different fc_function_templates for
|
||||
the physical port and the virtual port. The physical port's template
|
||||
would have the vport_create, vport_delete, and vport_disable functions,
|
||||
@ -373,14 +430,17 @@ Vport Creation:
|
||||
|
||||
Vport Disable/Enable:
|
||||
|
||||
The LLDD vport_disable() syntax is:
|
||||
The LLDD vport_disable() syntax is::
|
||||
|
||||
int vport_disable(struct fc_vport *vport, bool disable)
|
||||
|
||||
where:
|
||||
vport: Is vport to be enabled or disabled
|
||||
disable: If "true", the vport is to be disabled.
|
||||
where:
|
||||
|
||||
======= =======================================
|
||||
vport Is vport to be enabled or disabled
|
||||
disable If "true", the vport is to be disabled.
|
||||
If "false", the vport is to be enabled.
|
||||
======= =======================================
|
||||
|
||||
When a request is made to change the disabled state on a vport, the
|
||||
transport will validate the request against the existing vport state.
|
||||
@ -401,11 +461,12 @@ Vport Disable/Enable:
|
||||
|
||||
Vport Deletion:
|
||||
|
||||
The LLDD vport_delete() syntax is:
|
||||
The LLDD vport_delete() syntax is::
|
||||
|
||||
int vport_delete(struct fc_vport *vport)
|
||||
|
||||
where:
|
||||
where:
|
||||
|
||||
vport: Is vport to delete
|
||||
|
||||
When a request is made to delete a vport (via sgio/netlink, or via the
|
||||
@ -443,39 +504,42 @@ Transport supplied functions
|
||||
|
||||
The following functions are supplied by the FC-transport for use by LLDs.
|
||||
|
||||
fc_vport_create - create a vport
|
||||
fc_vport_terminate - detach and remove a vport
|
||||
================== =========================
|
||||
fc_vport_create create a vport
|
||||
fc_vport_terminate detach and remove a vport
|
||||
================== =========================
|
||||
|
||||
Details:
|
||||
Details::
|
||||
|
||||
/**
|
||||
* fc_vport_create - Admin App or LLDD requests creation of a vport
|
||||
* @shost: scsi host the virtual port is connected to.
|
||||
* @ids: The world wide names, FC4 port roles, etc for
|
||||
* the virtual port.
|
||||
*
|
||||
* Notes:
|
||||
* This routine assumes no locks are held on entry.
|
||||
*/
|
||||
struct fc_vport *
|
||||
fc_vport_create(struct Scsi_Host *shost, struct fc_vport_identifiers *ids)
|
||||
/**
|
||||
* fc_vport_create - Admin App or LLDD requests creation of a vport
|
||||
* @shost: scsi host the virtual port is connected to.
|
||||
* @ids: The world wide names, FC4 port roles, etc for
|
||||
* the virtual port.
|
||||
*
|
||||
* Notes:
|
||||
* This routine assumes no locks are held on entry.
|
||||
*/
|
||||
struct fc_vport *
|
||||
fc_vport_create(struct Scsi_Host *shost, struct fc_vport_identifiers *ids)
|
||||
|
||||
/**
|
||||
* fc_vport_terminate - Admin App or LLDD requests termination of a vport
|
||||
* @vport: fc_vport to be terminated
|
||||
*
|
||||
* Calls the LLDD vport_delete() function, then deallocates and removes
|
||||
* the vport from the shost and object tree.
|
||||
*
|
||||
* Notes:
|
||||
* This routine assumes no locks are held on entry.
|
||||
*/
|
||||
int
|
||||
fc_vport_terminate(struct fc_vport *vport)
|
||||
/**
|
||||
* fc_vport_terminate - Admin App or LLDD requests termination of a vport
|
||||
* @vport: fc_vport to be terminated
|
||||
*
|
||||
* Calls the LLDD vport_delete() function, then deallocates and removes
|
||||
* the vport from the shost and object tree.
|
||||
*
|
||||
* Notes:
|
||||
* This routine assumes no locks are held on entry.
|
||||
*/
|
||||
int
|
||||
fc_vport_terminate(struct fc_vport *vport)
|
||||
|
||||
|
||||
FC BSG support (CT & ELS passthru, and more)
|
||||
========================================================================
|
||||
============================================
|
||||
|
||||
<< To Be Supplied >>
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user