Currently you can specify the weight of the cooling device in the device
tree but that information is not populated to the
thermal_bind_params where the fair share governor expects it to
be. The of thermal zone device doesn't have a thermal_bind_params
structure and arguably it's better to pass the weight inside the
thermal_instance as it is specific to the bind of a cooling device to a
thermal zone parameter.
Core thermal code is fixed to populate the weight in the instance from
the thermal_bind_params, so platform code that was passing the weight
inside the thermal_bind_params continue to work seamlessly.
While we are at it, create a default value for the weight parameter for
those thermal zones that currently don't define it and remove the
hardcoded default in of-thermal.
Cc: Zhang Rui <rui.zhang@intel.com>
Cc: "Rafael J. Wysocki" <rjw@rjwysocki.net>
Cc: Len Brown <lenb@kernel.org>
Cc: Peter Feuerer <peter@piie.net>
Cc: Darren Hart <dvhart@infradead.org>
Cc: Eduardo Valentin <edubezval@gmail.com>
Cc: Kukjin Kim <kgene@kernel.org>
Cc: Durgadoss R <durgadoss.r@intel.com>
Signed-off-by: Kapileshwar Singh <kapileshwar.singh@arm.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
thermal_zone_device_register() returns ERR_PTR on error, thus use
IS_ERR rather than IS_ERR_OR_NULL to check return value.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This eliminates having an #ifdef returning NULL for the case
when OF is disabled.
Signed-off-by: Sachin Kamat <sachin.kamat@linaro.org>
Reviewed-by: Hongbo Zhang <hongbo.zhang@stericsson.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This driver is based on the thermal management framework in thermal_sys.c. A
thermal zone device is created with the trip points to which cooling devices
can be bound, the current cooling device is cpufreq, e.g. CPU frequency is
clipped down to cool the CPU, and other cooling devices can be added and bound
to the trip points dynamically. The platform specific PRCMU interrupts are
used to active thermal update when trip points are reached.
Signed-off-by: hongbo.zhang <hongbo.zhang@linaro.com>
Reviewed-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Francesco Lavra <francescolavra.fl@gmail.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>