This patch allows iscsiadm to manage iSCSI target information stored on
qla4xxx adapter flash on per host basis.
Signed-off-by: Adheer Chandravanshi <adheer.chandravanshi@qlogic.com>
Signed-off-by: Manish Rangankar <manish.rangankar@qlogic.com>
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
This patch allows iscsiadm to manage iSCSI target information stored on
adapter flash on per host basis.
The sysfs entries will look as cited below:
/sys/bus/iscsi_flashnode/devices/flashnode_sess-<host_no>:<flashnode_id>/<session attrs>
/sys/bus/iscsi_flashnode/devices/flashnode_conn-<host_no>:<flashnode_id>:<conn_id>/<conn attrs>
Signed-off-by: Adheer Chandravanshi <adheer.chandravanshi@qlogic.com>
Signed-off-by: Manish Rangankar <manish.rangankar@qlogic.com>
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
While probe Skip retry of initialize_adapter only for ISP82XX and ISP83XX.
We need to retry initialize_adapter for ISP40XX.
Signed-off-by: Nilesh Javali <nilesh.javali@qlogic.com>
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Reviewed-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Issue:
If flash read for FLT fails, we are assigning wrong default
address for CHAP table in FLT, which will cause CHAP table
read/write to wrong address.
Fix:
Assign correct default CHAP table address to FLT.
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Reviewed-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
The dereference to 'put_index' should be moved below the NULL test.
Signed-off-by: Wei Yongjun <yongjun_wei@trendmicro.com.cn>
Acked-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
This patch adds dual flash firmware support for Series 7 and above controllers.
[thenzl: used ssleep(10) instead udelay]
Signed-off-by: Mahesh Rajashekhara <Mahesh.Rajashekhara@pmcs.com>
Reviewed-by: Tomas Henzl <thenzl@redhat.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
The variable 'data' is initialized but never used
otherwise, so remove the unused variable.
Signed-off-by: Wei Yongjun <yongjun_wei@trendmicro.com.cn>
Acked-by: Naresh Kumar Inna <naresh@chelsio.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Issue:
Request queue count holds the information about free space in request queue
which has to be manipulated based on request in and out pointer.
But in driver response path, this count was incremented unconditionally,
which could move req_in pointer beyond req_out pointer.
This scenario leads fw hang during IO.
Solution:
Request queue count manipulation has to be done in IO path only, keeping
req_in and req_out pointer two IOCB count away
Signed-off-by: Tej Parkash <tej.parkash@qlogic.com>
Signed-off-by: Shyam Sundar <shyam.sundar@qlogic.com>
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Move "Incorrect function ID" print message in case INTX interrupt
from DEBUG2 to DEBUG7. This will avoid floods of this message if
DEBUG2 is enabled.
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Use function int_to_scsilun() in qla4xxx_reset_lun() to convert
integer value comming from scsi_transport to scsi LUN address format.
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
In case of firmware hung we need to call "mailbox_premature_completion" to
complete any pending mbox command as firmware is not alive.
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
For ISP83XX set graceful reset bit in IDC_DRV_CTRL
if reset is issued by application
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Issue:
ISP83XX check is missing in function get_fw_boot_info() because of this
qla4xxx will not export boot target to sysfs and iscsistart cannot issue
login to boot target.
Fix:
Added check for ISP83XX in function get_fw_boot_info()
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Problem Description:
Disabling pause frames might cause hardware wedging needing a power cycle.
This might happen if the Eport is not initialized and is in reset.
Solution:
Before disabling pause frames ensure that eport is out of reset.
Signed-off-by: Manish Dusane <manish.dusane@qlogic.com>
Signed-off-by: Vikas Chaudhary <vikas.chaudhary@qlogic.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
For the stpg_endio path we are not evaluating the sense. The bug
is that
1. The error value is set to -EIO when there is sense, so we hit the first
error check and always return SCSI_DH_IO.
2. h->senselen is set to zero in submit_stpg. It is not later set to
req->sense_len like in the synchrounous exection paths, so we must
check the req->sense_len field.
Signed-off-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
The service parameters for the VPI/RPIs were incorrect, resulting in
lower utilization
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Fixed NMI watch dog panic's when resetting the hba.
Signed-off-by: James Smart <james.smart@emulex.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
The only part of proc_dir_entry the code outside of fs/proc
really cares about is PDE(inode)->data. Provide a helper
for that; static inline for now, eventually will be moved
to fs/proc, along with the knowledge of struct proc_dir_entry
layout.
Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>
Some of the ->show_info() instances really spew a lot; it's not a problem
wrt correctness (seq_read() will grow buffer and call the sucker again),
but in this case it makes sense to start with a somewhat bigger one -
they often do exceed one page worth of output.
Signed-off-by: Al Viro <viro@zeniv.linux.org.uk>