In max17042_get_property(...), the values returned by
max17042_read_reg are directly assigned to the variables,
even if the read results in an error.
This patch checks for the return code from max17042_read_reg and
exits the function if there is any error.
Signed-off-by: Ramakrishna Pallala <ramakrishna.pallala@intel.com>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
The module.h header is no longer going to be implicitly present
everywhere. So real modular users need to call out its use
explicitly in advance.
[v2: add new users reported by Randy Dunlap <rdunlap@xenotime.net>]
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
The calculation had error in getting voltage values from
MAX17042 registers. The least bit denotes 78.125uV (625/8).
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Philip Rakity <prakity@marvell.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
PROP_CURRENT_NOW value is first divided then multiplied up
causing a lose of accuracy. Use the same method as
PROP_CURRENT_AVG to do the calculation.
Signed-off-by: Philip Rakity <prakity@marvell.com>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
On MMP2 brownstone divide by 0 error since probe sets r_sns
after calling power_supply_register.
Move the code up a few lines. r_sns comes from the platform
data.
PROP_CURRENT_AVG and PROP_CURRENT divide the result by r_sns.
Signed-off-by: Philip Rakity <prakity@marvell.com>
Acked-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This patch supports additional properties (PRESENT, CYCLE_COUNT,
VOLTAGE_MAX, VOLTAGE_MIN_DESIGN, CURRENT_NOW, CURRENT_AVG,
CHARGE_FULL, and TEMP).
Plus, initialization code for registers is added.
Signed-off-by: Donggeun Kim <dg77.kim@samsung.com>
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: KyungMin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
A few new i2c-drivers came into the kernel which clear the
clientdata-pointer on exit or error. This is obsolete meanwhile,
the core will do it.
Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
Cc: MyungJoo Ham <myungjoo.ham@samsung.com>
Cc: Kyungmin Park <kyungmin.park@samsung.com>
Acked-by: Jean Delvare <khali@linux-fr.org>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
The MAX17042 is a fuel gauge with an I2C interface for lithium-ion
betteries. Unlike its predecessor MAX17040, MAX17042 uses 16bit
registers. Besides, MAX17042 has much more features than MAX17040; e.g.,
a thermistor, current and current accumulation measurement, battery
internal resistance estimate, average values of measurement, and others.
This patch implements a driver for MAX17042.
In this initial release, we have implemented the most basic features of
a fuel gauge: measure the battery capacity and voltage.
Signed-off-by: MyungJoo Ham <myungjoo.ham@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>