IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
The xlate callbacks are supposed to translate of_phandle_args to proper
provider without modifying the of_phandle_args. Make the argument
pointer to const for code safety and readability.
Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Acked-by: Thierry Reding <treding@nvidia.com>
Acked-by: Linus Walleij <linus.walleij@linaro.org>
Acked-by: Florian Fainelli <florian.fainelli@broadcom.com> #Broadcom
Link: https://lore.kernel.org/r/20240217093937.58234-1-krzysztof.kozlowski@linaro.org
Signed-off-by: Vinod Koul <vkoul@kernel.org>
Implement Exynos850 USB 2.0 DRD PHY controller support. Exynos850 has
quite a different PHY controller than Exynos5 compatible controllers,
but it's still possible to implement it on top of existing
exynos5-usbdrd driver infrastructure.
Only UTMI+ (USB 2.0) PHY interface is implemented, as Exynos850 doesn't
support USB 3.0.
Only two clocks are used for this controller:
- phy: bus clock, used for PHY registers access
- ref: PHY reference clock (OSCCLK)
Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Link: https://lore.kernel.org/r/20230819031731.22618-7-semen.protsenko@linaro.org
Signed-off-by: Vinod Koul <vkoul@kernel.org>
Modern Exynos chips (like Exynos850) might have 26 MHz OSCCLK external
clock, which is also used as a PHY reference clock. For some USB PHY
controllers (e.g USB DRD PHY block on Exynos850) there is no need to set
the refclk frequency at all (and corresponding bits in CLKRSTCTRL[7:5]
are marked RESERVED), so that value won't be set in the driver. But
even in that case, 26 MHz support still has to be added, otherwise
exynos5_rate_to_clk() fails, which leads in turn to probe error.
Add the correct value for 26MHz refclk to make it possible to add
support for new Exynos USB DRD PHY controllers.
Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Link: https://lore.kernel.org/r/20230819031731.22618-6-semen.protsenko@linaro.org
Signed-off-by: Vinod Koul <vkoul@kernel.org>
Provide a way to use different PHY ops for different chips. Right now
all chips are using exynos5_usbdrd_phy_ops, but it won't always be the
case. For example, Exynos850 has very different USB PHY block, so there
will be another PHY ops implementation for that chip.
No functional change.
Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Link: https://lore.kernel.org/r/20230819031731.22618-5-semen.protsenko@linaro.org
Signed-off-by: Vinod Koul <vkoul@kernel.org>
The DT of_device.h and of_platform.h date back to the separate
of_platform_bus_type before it as merged into the regular platform bus.
As part of that merge prepping Arm DT support 13 years ago, they
"temporarily" include each other. They also include platform_device.h
and of.h. As a result, there's a pretty much random mix of those include
files used throughout the tree. In order to detangle these headers and
replace the implicit includes with struct declarations, users need to
explicitly include the correct includes.
Signed-off-by: Rob Herring <robh@kernel.org>
Acked-by: Marc Kleine-Budde <mkl@pengutronix.de> # for drivers/phy/phy-can-transceiver.c
Acked-by: Heiko Stuebner <heiko@sntech.de>
Acked-by: Sergio Paracuellos <sergio.paracuellos@gmail.com>
Link: https://lore.kernel.org/r/20230714174841.4061919-1-robh@kernel.org
Signed-off-by: Vinod Koul <vkoul@kernel.org>
Instead of a busy waiting while loop using udelay
use readl_poll_timeout function to check the condition
is met or timeout occurs in crport_handshake function.
readl_poll_timeout is called in non atomic context so
it safe to sleep until the condition is met.
Signed-off-by: Anand Moon <linux.amoon@gmail.com>
Link: https://lore.kernel.org/r/20200720173502.542-1-linux.amoon@gmail.com
Signed-off-by: Vinod Koul <vkoul@kernel.org>
We get warning with W=1 build:
drivers/phy/samsung/phy-exynos5-usbdrd.c:211: warning: Function
parameter or member 'phys' not described in 'exynos5_usbdrd_phy'
drivers/phy/samsung/phy-exynos5-usbdrd.c:211: warning: Function
parameter or member 'vbus' not described in 'exynos5_usbdrd_phy'
drivers/phy/samsung/phy-exynos5-usbdrd.c:211: warning: Function
parameter or member 'vbus_boost' not described in 'exynos5_usbdrd_phy'
These members are provided with description but format is not quite
right resulting in above warnings
Acked-by: Marek Szyprowski <m.szyprowski@samsung.com>
Link: https://lore.kernel.org/r/20200708132809.265967-5-vkoul@kernel.org
Signed-off-by: Vinod Koul <vkoul@kernel.org>
PHY calibration is needed only for USB2.0 (UTMI) PHY, so skip calling
calibration code when phy_calibrate() is called for USB3.0 (PIPE3) PHY.
Fixes: d8c80bb3b55b ("phy: exynos5-usbdrd: Calibrate LOS levels for exynos5420/5800")
Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
Acked-by: Krzysztof Kozlowski <krzk@kernel.org>
Link: https://lore.kernel.org/r/20200708133800.3336-1-m.szyprowski@samsung.com
Signed-off-by: Vinod Koul <vkoul@kernel.org>
Fix up inconsistent usage of upper and lowercase letters in "Exynos"
name.
"EXYNOS" is not an abbreviation but a regular trademarked name.
Therefore it should be written with lowercase letters starting with
capital letter.
The lowercase "Exynos" name is promoted by its manufacturer Samsung
Electronics Co., Ltd., in advertisement materials and on website.
Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org>
Link: https://lore.kernel.org/r/20200617152803.17941-1-krzk@kernel.org
Signed-off-by: Vinod Koul <vkoul@kernel.org>
Samsung PHY drivers control the power to the SoC core components needed by
their client devices (USB HCDs, SATA, camera ISP bridge, DP encoder) to
properly operate. Disabling PHYs in runtime usually causes the client
device to crash with external abort exception or similar issue due to lack
of API to notify clients about PHY removal. This patch removes the
possiblity to unbind Samsung Exynos PHY drivers in runtime.
Signed-off-by: Marek Szyprowski <m.szyprowski@samsung.com>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Based on 2 normalized pattern(s):
this program is free software you can redistribute it and or modify
it under the terms of the gnu general public license version 2 as
published by the free software foundation
this program is free software you can redistribute it and or modify
it under the terms of the gnu general public license version 2 as
published by the free software foundation #
extracted by the scancode license scanner the SPDX license identifier
GPL-2.0-only
has been chosen to replace the boilerplate/reference in 4122 file(s).
Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Reviewed-by: Enrico Weigelt <info@metux.net>
Reviewed-by: Kate Stewart <kstewart@linuxfoundation.org>
Reviewed-by: Allison Randal <allison@lohutok.net>
Cc: linux-spdx@vger.kernel.org
Link: https://lkml.kernel.org/r/20190604081206.933168790@linutronix.de
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Adding phy calibration sequence for USB 3.0 DRD PHY present on
Exynos5420/5800 systems.
This calibration facilitates setting certain PHY parameters viz.
the Loss-of-Signal (LOS) Detector Threshold Level, as well as
Tx-Vboost-Level for Super-Speed operations.
Additionally we also set proper time to wait for RxDetect measurement,
for desired PHY reference clock, so as to solve issue with enumeration
of few USB 3.0 devices, like Samsung SUM-TSB16S 3.0 USB drive
on the controller.
We are using CR_port for this purpose to send required data
to override the LOS values.
On testing with USB 3.0 devices on USB 3.0 port present on
SMDK5420, and peach-pit boards should see following message:
usb 2-1: new SuperSpeed USB device number 2 using xhci-hcd
and without this patch, should see below shown message:
usb 1-1: new high-speed USB device number 2 using xhci-hcd
[Also removed unnecessary extra lines in the register macro definitions]
Signed-off-by: Vivek Gautam <gautam.vivek@samsung.com>
[adapted to use phy_calibrate as entry point]
Signed-off-by: Andrzej Pietrasiewicz <andrzej.p@samsung.com>
Acked-by: Felipe Balbi <felipe.balbi@linux.intel.com>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>
reduce the boilerplate code to get the specific data
Signed-off-by: Chunfeng Yun <chunfeng.yun@mediatek.com>
Signed-off-by: Kishon Vijay Abraham I <kishon@ti.com>