600 Commits

Author SHA1 Message Date
Linus Torvalds
e6b5be2be4 Driver core patches for 3.19-rc1
Here's the set of driver core patches for 3.19-rc1.
 
 They are dominated by the removal of the .owner field in platform
 drivers.  They touch a lot of files, but they are "simple" changes, just
 removing a line in a structure.
 
 Other than that, a few minor driver core and debugfs changes.  There are
 some ath9k patches coming in through this tree that have been acked by
 the wireless maintainers as they relied on the debugfs changes.
 
 Everything has been in linux-next for a while.
 
 Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
 -----BEGIN PGP SIGNATURE-----
 Version: GnuPG v2
 
 iEYEABECAAYFAlSOD20ACgkQMUfUDdst+ylLPACg2QrW1oHhdTMT9WI8jihlHVRM
 53kAoLeteByQ3iVwWurwwseRPiWa8+MI
 =OVRS
 -----END PGP SIGNATURE-----

Merge tag 'driver-core-3.19-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/driver-core

Pull driver core update from Greg KH:
 "Here's the set of driver core patches for 3.19-rc1.

  They are dominated by the removal of the .owner field in platform
  drivers.  They touch a lot of files, but they are "simple" changes,
  just removing a line in a structure.

  Other than that, a few minor driver core and debugfs changes.  There
  are some ath9k patches coming in through this tree that have been
  acked by the wireless maintainers as they relied on the debugfs
  changes.

  Everything has been in linux-next for a while"

* tag 'driver-core-3.19-rc1' of git://git.kernel.org/pub/scm/linux/kernel/git/gregkh/driver-core: (324 commits)
  Revert "ath: ath9k: use debugfs_create_devm_seqfile() helper for seq_file entries"
  fs: debugfs: add forward declaration for struct device type
  firmware class: Deletion of an unnecessary check before the function call "vunmap"
  firmware loader: fix hung task warning dump
  devcoredump: provide a one-way disable function
  device: Add dev_<level>_once variants
  ath: ath9k: use debugfs_create_devm_seqfile() helper for seq_file entries
  ath: use seq_file api for ath9k debugfs files
  debugfs: add helper function to create device related seq_file
  drivers/base: cacheinfo: remove noisy error boot message
  Revert "core: platform: add warning if driver has no owner"
  drivers: base: support cpu cache information interface to userspace via sysfs
  drivers: base: add cpu_device_create to support per-cpu devices
  topology: replace custom attribute macros with standard DEVICE_ATTR*
  cpumask: factor out show_cpumap into separate helper function
  driver core: Fix unbalanced device reference in drivers_probe
  driver core: fix race with userland in device_add()
  sysfs/kernfs: make read requests on pre-alloc files use the buffer.
  sysfs/kernfs: allow attributes to request write buffer be pre-allocated.
  fs: sysfs: return EGBIG on write if offset is larger than file size
  ...
2014-12-14 16:10:09 -08:00
Zhang Rui
2707dbd09a Merge branches 'thermal-core-fix', 'thermal-soc' and 'thermal-int340x' into next 2014-12-13 12:25:19 +08:00
Eduardo Valentin
cffafc3247 thermal: ti-soc-thermal: Do not print error message in the EPROBE_DEFER case
Avoid printing the error message in the EPROBE_DEFER case
where registering cpu cooling at ti-soc-thermal thermal driver.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-12 10:08:31 -04:00
Eduardo Valentin
38cbf0414c thermal: db8500: Do not print error message in the EPROBE_DEFER case
Avoid printing the error message in the EPROBE_DEFER case
where registering cpu cooling at db8500 thermal driver.

Cc: Zhang Rui <rui.zhang@intel.com>
Cc: Grant Likely <grant.likely@linaro.org>
Cc: Rob Herring <robh+dt@kernel.org>
Cc: linux-pm@vger.kernel.org
Cc: linux-kernel@vger.kernel.org
Cc: devicetree@vger.kernel.org
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-12 10:08:07 -04:00
Fabio Estevam
412aff9497 thermal: imx: Do not print error message in the EPROBE_DEFER case
During imx_thermal probe we have the following log:

[    1.514819] imx_thermal 2000000.aips-bus:tempmon: failed to register cpufreq cooling device: -517
[    1.515064] platform 2000000.aips-bus:tempmon: Driver imx_thermal requests probe deferral

Avoid printing the error message in the EPROBE_DEFER case.

Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-12 09:53:46 -04:00
Abhilash Kesavan
fcbb1e02ee drivers: thermal: Remove ARCH_HAS_BANDGAP dependency for samsung
As samsung thermal support is enabled only for ARCH_EXYNOS, there is no
need to select ARCH_HAS_BANDGAP from the arch-specific code. Removing this
dependency will also allow the driver to be enabled on 64-bit SoCs.

Reviewed-by: Bartlomiej Zolnierkiewicz <b.zolnierkie@samsung.com>
Reviewed-by: Lukasz Majewski <l.majewski@samsung.com>
Acked-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Abhilash Kesavan <a.kesavan@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-10 11:06:18 -04:00
Ilkka Koskinen
e413ad7cca Thermal/int340x: Clear the error value of the last acpi_bus_get_device() call
Previously the return value of the last acpi_bus_get_device() was
returned. However, since we only report those issues, it should be
cleared to continue as expected.

Signed-off-by: Ilkka Koskinen <ilkka.koskinen@linux.intel.com>
Acked-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
2014-12-09 14:05:05 +08:00
Zhang Rui
c89d99546d Merge branch 'eduardo-soc-thermal' into thermal-soc 2014-12-09 11:38:34 +08:00
Jacob Pan
5a530ff0d8 thermal/powerclamp: add id for braswell cpu
Braswell also has package C-states which can be used for idle
injection. This patch adds Braswell CPU ID in intel powerclamp
driver.

Signed-off-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:38:17 +08:00
Maurice Petallo
05629296ee thermal: Intel SoC DTS: Don't do thermal zone update inside spin_lock
The driver calls spin_lock_irqsave during DTS interrupt. The interrupt
handle then calls thermal_zone_device_update which implicitly calls
a sleep function and produce the following bug:

BUG: sleeping function called from invalid context at kernel/locking/mutex.c:97
in_atomic(): 1, irqs_disabled(): 1, pid: 920, name: irq/86-soc_dts
CPU: 0 PID: 920 Comm: irq/86-soc_dts Tainted: G            E  3.17.0-rc2+ #1
Hardware name: Intel Corp. VALLEYVIEW B3 PLATFORM/NOTEBOOK, BIOS BYTICRB1.86C.0092.R31.1408290850 08/29/2014
 00000000 00000000 c25dbe74 c1818cfd f3cc488c c25dbe9c c1059305 c1b4063b
 00000001 00000001 00000398 f3cc488c f6817644 f6817644 f3ecc6c0 c25dbea8
 c18208f2 f6817400 c25dbebc c159b0bb c25dbedc f6817400 f32a2300 c25dbee8
Call Trace:
 [<c1818cfd>] dump_stack+0x48/0x60
 [<c1059305>] __might_sleep+0xec/0xf4
 [<c18208f2>] mutex_lock+0x1c/0x34
 [<c159b0bb>] thermal_zone_get_temp+0x34/0x59
 [<c159bde5>] thermal_zone_device_update+0x2d/0xcb
 [<f85da16a>] ? iosf_mbi_write+0x6c/0x74 [iosf_mbi]
 [<f7c7445d>] soc_irq_thread_fn+0x10c/0x163 [intel_soc_dts_thermal]
 [<c107b72b>] irq_thread_fn+0x18/0x2a
 [<c107bedb>] irq_thread+0x81/0x11f
 [<c107b713>] ? irq_finalize_oneshot+0x7c/0x7c
 [<c107bf79>] ? irq_thread+0x11f/0x11f
 [<c107be5a>] ? wake_threads_waitq+0x31/0x31
 [<c1054217>] kthread+0x87/0x8c
 [<c1821e41>] ret_from_kernel_thread+0x21/0x30
 [<c1054190>] ? __kthread_parkme+0x55/0x55

Signed-off-by: Maurice Petallo <mauricex.r.petallo@intel.com>
Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Acked-by: Eduardo Valentin <edubezval@gmail.com>
CC: Kweh, Hock Leong <hock.leong.kweh@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:38:16 +08:00
Zhang Rui
9c1e4550b5 Merge branch 'linus' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal into eduardo-soc-thermal 2014-12-09 11:37:35 +08:00
Wu Fengguang
341203167f Thermal: fix platform_no_drv_owner.cocci warnings
drivers/thermal/int340x_thermal/int3403_thermal.c:468:3-8: No need to set .owner here. The core will do it.

 Remove .owner field if calls are used which set it automatically

Generated by: scripts/coccinelle/api/platform_no_drv_owner.cocci

Signed-off-by: Fengguang Wu <fengguang.wu@intel.com>
Acked-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:31:20 +08:00
Jacob Pan
b81e5962af Thermal/int340x: avoid unnecessary pointer casting
Avoid pointer casting which may also lead to problems on big endian
64 bit systems.

Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Jacob Pan <jacob.jun.pan@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:31:19 +08:00
Markus Elfring
931b9c86d9 thermal: int3403: Delete a check before thermal_zone_device_unregister()
The thermal_zone_device_unregister() function tests whether its argument
is NULL and then returns immediately. Thus the test around the call
is not needed.

This issue was detected by using the Coccinelle software.

Signed-off-by: Markus Elfring <elfring@users.sourceforge.net>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:31:18 +08:00
Srinivas Pandruvada
19ecaea268 thermal/int3400: export uuids
INT3400 currently supports only one policy, which can't be changed.
This change exports all available policies (uuids) to user space and
allow this to be changed.
It introduces an attribute group uuids in INT3400 platform driver.
There are two attributes exposed:
- available_uuids
- current_uuid

User space can set current_uuid via this interface to one of the
available uuids. The uuid change is communicated to firmware, only
when the current zone mode is changed to "enabled". So the ideal
sequence should be
- set INT3400 zone mode to "disabled"
- change current_uuid
- set INT3400 zone mode to "enabled"

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-09 11:31:17 +08:00
Lukasz Majewski
9a3031dc3e thermal:core:fix: Check return code of the ->get_max_state() callback
The return code from ->get_max_state() callback was not checked during
binding cooling device to thermal zone device.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 21:32:56 -04:00
Lukasz Majewski
184a4bf623 thermal: of: Extend current of-thermal.c code to allow setting emulated temp
Before this change it was only possible to set get_temp() and get_trend()
methods to be used in the common code handling passing parameters via
device tree to "cpu-thermal" CPU thermal zone device.

Now it is possible to also set emulated value of temperature for debug
purposes.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 21:10:00 -04:00
Lukasz Majewski
ce8be77859 thermal: of: Extend of-thermal to export table of trip points
This patch extends the of-thermal.c to export trip points for a given
thermal zone.

Thermal drivers should use of_thermal_get_trip_points() method to get
pointer to table of thermal trip points.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 15:58:01 -04:00
Lukasz Majewski
ad9914ac3b thermal: of: Rename struct __thermal_trip to struct thermal_trip
This patch changes name of struct __thermal_trip to thermal_trip and moves
declaration of the latter to ./include/linux/thermal.h for better visibility.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 15:53:55 -04:00
Lukasz Majewski
a9bf2cc49d thermal: of: Extend of-thermal.c to provide check if trip point is valid
This patch extends the of-thermal.c to provide check if trip point is
valid.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 15:45:29 -04:00
Lukasz Majewski
08dab66ec8 thermal: of: Extend of-thermal.c to provide number of trip points
This patch extends the of-thermal.c to provide information about number of
available trip points.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 15:38:32 -04:00
Viresh Kumar
73904cbc1a thermal: cpu_cooling: update copyright tags
Adding my copyright information for two purposes:
- To get cc'd for future patches to review (Only if people read this header
  while sending mail)
- Have done enough changes to earn a place here?

Cc: Amit Daniel Kachhap <amit.daniel@samsung.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:12:37 -04:00
Viresh Kumar
4843c4a190 thermal: cpu_cooling: Use cpufreq_dev->freq_table for finding level/freq
get_property() was an over complicated beast with BUGs. It used to believe that
cpufreq table is present in ascending or descending order, which might not
always be true.

Previous patch has created another freq table in descending order for us and we
better use it now. With that get_property() simply goes away and another helper
get_level() comes in.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:11:54 -04:00
Viresh Kumar
f6859014c7 thermal: cpu_cooling: Store frequencies in descending order
CPUFreq framework *doesn't* guarantee that frequencies present in cpufreq table
will be in ascending or descending order. But cpu_cooling somehow assumes that.

Probably because most of current users are creating this list from DT, which is
done with the help of OPP layer. And OPP layer creates the list in ascending
order of frequencies.

But cpu_cooling can be used for other platforms too, which don't have
frequencies arranged in any order.

This patch tries to fix this issue by creating another list of valid frequencies
in descending order. Care is also taken to throw warnings for duplicate entries.

Later patches would use it to simplify code.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:11:02 -04:00
Viresh Kumar
b9f8b41603 thermal: cpu_cooling: Pass 'cpufreq_dev' to get_property()
We already know the value of 'cpufreq_dev->max_level' and so there is no need
calculating that once again. For this, we need to send 'cpufreq_dev' to
get_property().

Make all necessary changes for this change. Because cpufreq_cooling_get_level()
doesn't have access to 'cpufreq_dev', it is updated to iterate over the list of
cpufreq_cooling_devices to get cooling device for the cpu number passed to it.
This also makes it robust to return levels only for the CPU registered via a
cooling device. We don't have to support anything that isn't registered yet.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:10:08 -04:00
Viresh Kumar
2479bb6443 thermal: cpu_cooling: use cpufreq_dev_list instead of cpufreq_dev_count
As we already have a list of cpufreq_cooling_devices now, lets use it instead of
a local counter.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:09:15 -04:00
Viresh Kumar
97afa4aafb thermal: cpu_cooling: get_property() doesn't need to support GET_MAXL anymore
We don't use get_property() to find max levels anymore as it is done at boot
now. So, don't support GET_MAXL in get_property().

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:08:05 -04:00
Viresh Kumar
dcc6c7fdef thermal: cpu_cooling: find max level during device registration
CPU frequency tables don't update after the driver is registered and so we don't
need to iterate over them to find total number of states every time
cpufreq_get_max_state() is called. Do it once at boot time.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:07:10 -04:00
Viresh Kumar
521a2e5831 thermal: cpu_cooling: remove unnecessary wrapper get_cpu_frequency()
get_cpu_frequency() isn't doing much by itself, just calling get_property(). And
so this wrapper isn't required at all. Get rid of it.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:05:53 -04:00
Viresh Kumar
5194fe4699 thermal: cpu_cooling: Merge cpufreq_apply_cooling() into cpufreq_set_cur_state()
cpufreq_apply_cooling() has a single caller, cpufreq_set_cur_state() and
cpufreq_set_cur_state() is an unnecessary wrapper over cpufreq_apply_cooling().

Get rid of it by merging both routines.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 14:04:56 -04:00
Viresh Kumar
7adb635b3c thermal: cpu_cooling: initialize 'cpufreq_val' on registration
There is no point checking for validity of 'cpufreq_val' from
cpufreq_thermal_notifier() every time the routine is called. Its guaranteed to
be 0 on the first call but will be valid otherwise.

Lets update it once while the device registers.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:09:52 -04:00
Viresh Kumar
730abe064b thermal: cpu_cooling: do error handling at the bottom in __cpufreq_cooling_register()
This makes life easy and bug free. And is scalable for future resource
allocations.

Acked-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:57 -04:00
Viresh Kumar
c9ca319f05 thermal: cpu_cooling: Don't check is_cpufreq_valid()
Because get_cpu_frequency() has returned a valid frequency, it means that the
cpufreq policy is surely valid and so no point checking that again with
is_cpufreq_valid(). Get rid of the routine as well as there are no more users.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:57 -04:00
Viresh Kumar
e1fae554fb thermal: cpu_cooling: don't iterate over all allowed_cpus to update cpufreq policy
All CPUs present in 'allowed_cpus' share the same 'struct cpufreq_policy'
structure and so calling cpufreq_update_policy() for each of them doesn't make
sense.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:56 -04:00
Viresh Kumar
405fb82562 thermal: cpu_cooling: Don't match min/max frequencies for all CPUs on cooling register
In __cpufreq_cooling_register() we try to match min/max frequencies for all CPUs
passed in 'clip_cpus' mask. This mask is the cpumask of cpus where the frequency
constraints will be applied.

Same frequency constraint can be applied only to the CPUs belonging to the same
cluster (i.e. CPUs sharing clock line). For all such CPUs we have a single
'struct cpufreq_policy' structure managing them and so getting policies for all
CPUs wouldn't make any sense as they will all return the same pointer.

So, remove this useless check of checking min/max for all CPUs. Also update doc
comment to make this more obvious that clip_cpus should be same as
policy->related_cpus.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:56 -04:00
Viresh Kumar
268ac445ee thermal: cpu_cooling: propagate error returned by idr_alloc()
We aren't supposed to return our own error type here. Return what we got.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:56 -04:00
Viresh Kumar
8e54d442fe thermal: cpu_cooling: no need to initialze 'ret'
ret is initialized before it is used, so no need to set it to 0 in its declaration.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:56 -04:00
Viresh Kumar
5d3bdb8998 thermal: cpu_cooling: no need to set cpufreq_dev to NULL
It will be overwritten soon with return value of kzalloc().

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:55 -04:00
Viresh Kumar
92e615ec82 thermal: cpu_cooling: no need to set cpufreq_state to zero
Its already zero, we allocated cpufreq_dev with kzalloc.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:55 -04:00
Viresh Kumar
98d522f056 thermal: cpu_cooling: Pass variable instead of its type to sizeof()
Just following coding guidelines here.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:55 -04:00
Viresh Kumar
07d888d831 thermal: cpu_cooling: Add comment to clarify relation between cooling state and frequency
This wasn't explained well anywhere and should be clearly specified. Lets add a
top level comment for this.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:55 -04:00
Viresh Kumar
beca6053fc thermal: cpu_cooling: fix doc comment over struct cpufreq_cooling_device
cooling_cpufreq_lock isn't used to protect this structure and so the comment
over it is outdated. Fix it.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:54 -04:00
Viresh Kumar
728c03c959 thermal: cpu_cooling: random comment fixups
s/give/given

Acked-by: Eduardo Valentin <edubezval@gmail.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:54 -04:00
Viresh Kumar
f3764e6c18 thermal: exynos: pass cpu_present_mask to cpufreq_cooling_register()
cpufreq_cooling_register() expects mask of all the CPUs where frequency
constraint is applicable.

This platform has more than one CPU to which these constraints will apply and so
passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a
single cluster of CPUs and the constraint applies to all CPUs.

If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework
isn't aware of any siblings sharing clock line.

Fix it by passing cpu_present_mask to cpufreq_cooling_register().

Cc: Chanwoo Choi <cw00.choi@samsung.com>
Cc: Kyungmin Park <kyungmin.park@samsung.com>
Cc: Amit Daniel Kachhap <amit.daniel@samsung.com>
Cc: Lukasz Majewski <l.majewski@samsung.com>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:54 -04:00
Viresh Kumar
bec85d2e0c thermal: imx: pass cpu_present_mask to cpufreq_cooling_register()
cpufreq_cooling_register() expects mask of all the CPUs where frequency
constraint is applicable.

This platform has more than one CPU to which these constraints will apply and so
passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a
single cluster of CPUs and the constraint applies to all CPUs.

If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework
isn't aware of any siblings sharing clock line.

Fix it by passing cpu_present_mask to cpufreq_cooling_register().

Cc: Shawn Guo <shawn.guo@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:54 -04:00
Viresh Kumar
b45257b10d thermal: db8500: pass cpu_present_mask to cpufreq_cooling_register()
cpufreq_cooling_register() expects mask of all the CPUs where frequency
constraint is applicable.

This platform has more than one CPU to which these constraints will apply and so
passing mask of only CPU0 wouldn't be sufficient. Also, this platform has a
single cluster of CPUs and the constraint applies to all CPUs.

If CPU0 is hoplugged out then we may face strange BUGs as cpu_cooling framework
isn't aware of any siblings sharing clock line.

Fix it by passing cpu_present_mask to cpufreq_cooling_register().

Cc: Hongbo Zhang <hongbo.zhang@linaro.com>
Cc: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:54 -04:00
Eduardo Valentin
0f1be51c35 thermal: cpu_cooling: check for the readiness of cpufreq layer
In this patch, the cpu_cooling code checks for the usability of cpufreq
layer before proceeding with the CPU cooling device registration. The
main reason is: CPU cooling device is not usable if cpufreq cannot
switch frequencies.

Similar checks are spread in thermal drivers. Thus, the advantage now
is to have the check in a single place: cpu cooling device registration.
For this reason, this patch also updates the existing drivers that
depend on CPU cooling to simply propagate the error code of the cpu
cooling registration call. Therefore, in case cpufreq is not ready, the
thermal drivers will still return -EPROBE_DEFER, in an attempt to try
again when cpufreq layer gets ready.

Cc: devicetree@vger.kernel.org
Cc: Grant Likely <grant.likely@linaro.org>
Cc: Kukjin Kim <kgene.kim@samsung.com>
Cc: linux-arm-kernel@lists.infradead.org
Cc: linux-kernel@vger.kernel.org
Cc: linux-pm@vger.kernel.org
Cc: linux-samsung-soc@vger.kernel.org
Cc: Naveen Krishna Chatradhi <ch.naveen@samsung.com>
Cc: Rob Herring <robh+dt@kernel.org>
Cc: Zhang Rui <rui.zhang@intel.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
2014-12-08 12:08:53 -04:00
Luis Henriques
9d367e5e7b thermal: Fix error path in thermal_init()
thermal_unregister_governors() and class_unregister() were being called in
the wrong order.

Fixes: 80a26a5c22b9 ("Thermal: build thermal governors into thermal_sys module")
Cc: stable@vger.kernel.org
Signed-off-by: Luis Henriques <luis.henriques@canonical.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-08 12:17:25 +08:00
Javi Merino
b6cc772f64 thermal: lock the thermal zone when switching governors
Currently, userspace can request a governor change while the governor
itself is running.  Grab the thermal zone lock when changing the
governor to prevent this race.

Signed-off-by: Javi Merino <javi.merino@arm.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-08 12:10:44 +08:00
Srinivas Pandruvada
84ffe3ecc2 thermal: core: ignore invalid trip temperature
Ignore invalid trip temperature less or equal to zero. Some
buggy systems have invalid trips, causing system shutdown.

Signed-off-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com>
Signed-off-by: Zhang Rui <rui.zhang@intel.com>
2014-12-08 11:51:46 +08:00