There is little obvious use case for a regualtor driver to know if it is
possible to vary voltages at all by itself. If a consumer needs to
limit what voltages it tries to set based on the system configuration
then it will need to enumerate the possible voltages, and without that
even if it is possible to change voltages that doesn't mean that
constraints or other consumers will allow whatever change the driver is
trying to do at a given time. It doesn't even indicate if _set_voltage()
calls will work as noop _set_voltage() calls return success.
There were no users of this API that weren't abusing it and now they're
all gone so remove the API.
Signed-off-by: Mark Brown <broonie@kernel.org>
The TWL6030_FIXED_LDO() macro passes the TWL_FIXED_LDO()
macro an 0x0 instead of a NULL. Changing this to a NULL
fixes the following warnings:
drivers/regulator/twl-regulator.c:1068:1: warning: Using plain integer as NULL pointer
drivers/regulator/twl-regulator.c:1069:1: warning: Using plain integer as NULL pointer
drivers/regulator/twl-regulator.c:1070:1: warning: Using plain integer as NULL pointer
drivers/regulator/twl-regulator.c:1071:1: warning: Using plain integer as NULL pointer
drivers/regulator/twl-regulator.c:1072:1: warning: Using plain integer as NULL pointer
drivers/regulator/twl-regulator.c:1073:1: warning: Using plain integer as NULL pointer
Signed-off-by: Ben Dooks <ben.dooks@codethink.co.uk>
Signed-off-by: Mark Brown <broonie@kernel.org>
After "regulator: qcom_smd: add list_voltage callback" patch adding
pm8941 lnldo regulators would bug on list_voltages as it is a fixed
regulator without any linear range.
This patch fixes that issue by adding dedicated ops for pm8941 lnldo
without list_voltages callback.
Signed-off-by: Srinivas Kandagatla <srinivas.kandagatla@linaro.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Cc: stable@vger.kernel.org # v4.6
This patch adds support to list_voltage callback, so that consumers
like mmc core, can get information of supported voltage range.
Without this patch there is no way for mmc core to know this voltage range.
Signed-off-by: Srinivas Kandagatla <srinivas.kandagatla@linaro.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Cc: stable@vger.kernel.org # v4.6
Adjust the MODULE_DESCRIPTION() text to also include the PFUZE3000
as a supported device.
Signed-off-by: Fabio Estevam <fabio.estevam@nxp.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The CONFIG_REGULATOR_PFUZE100 option also supports PFUZE3000, so
mention that in the Kconfig text.
Signed-off-by: Fabio Estevam <fabio.estevam@nxp.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
We should better not use a global 'struct pfuze_regulator' variable,
as this could cause problems if multiple regulator chips are used.
Place it inside the private struct instead.
Signed-off-by: Fabio Estevam <fabio.estevam@nxp.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The axp20x pmics have 2 power inputs, one called ACIN which is intended
for to be supplied via a powerbarrel on the board and one called VBUS
which is intended to be supplied via an otg connector.
In the VBUS case the pmic needs to know if the board is supplying power
to the otg connector, because then it should not take any power from
its VBUS pin. The axp209 pmic has a N_VBUSEN input pin via which the
board can signal to the pmic whether the board is supplying power to the
otg connector or not.
On the axp221/axp223 this pin can alternatively be used as an output
which controls an external regulator which (optionally) supplies
power to the otg connector from the board. When the pin is used as
output it is called DRIVEVBUS in the datasheet.
This commit adds support for the DRIVEVBUS pin as an extra pmic
controlled regulator. Since this is optional a new x-powers,drivebus dt
property is added. When this is present the misc-control register is
written to change the N_VBUSEN input pin to DRIVEVBUS output pin mode and
the extra drivebus regulator is registered with the regulator subsystem.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
Now that the PWM regulator driver implements the ->enable/disable() hooks
we can remove the pwm_enable() call from pwm_regulator_set_voltage().
Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Add support to retrieve fixed voltage configure information through
ACPI interface. This is needed for Intel Bay Trail devices, where a
GPIO is used to control the USB vbus.
Signed-off-by: Lu Baolu <baolu.lu@linux.intel.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The X-Powers AXP809 PMIC has a similar set of regulators as the AXP221,
though a few LDOs were removed, and a new switch output added. Like the
AXP221, AXP809 also has DC1SW and DC5LDO, which are internally chained
to DCDC1 and DCDC5, respectively.
Add support for this new variant. Also remove the "axp22x_" prefix from
DC1SW/DC5LDO supply handling code, as the AXP809 uses it as well.
Signed-off-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
According to the datasheet:
SLEW Register(Address = 07h)
b7 b6 b5 b4 b3 b2 b1 b0
48mV/us 42mV/us 36mV/us 30mV/us 24mV/us 18mV/us 12mV/us 6mV/us
Current code does not set correct slew rate in some cases:
e.g. Assume ramp_delay is 10000, current code sets slew register to 6mV/us.
Fix the logic to set slew register.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Current code can set ramp delay to a wrong setting that the return value
from .set_voltage_time_sel is not enough for proper delay.
Fix the logic in .set_ramp_delay and also remove unused ret_val variable.
Signed-off-by: Axel Lin <axel.lin@ingics.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
BUCKs of mt6397 have auto mode and pwm mode.
User can use regulator interfaces to control modes
Signed-off-by: Henry Chen <henryc.chen@mediatek.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The GPIO interface of_get_named_gpio() has implemented the proper
error returns even EPROBE_DEFER and hence caller need not to
implement any workaround for translating the returned error.
Remove the workaround implemented to handle the return of
of_get_named_gpio().
Signed-off-by: Laxman Dewangan <ldewangan@nvidia.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
A common simplified DT parsing code for regulators was introduced in
commit a0c7b164ad11 ("regulator: of: Provide simplified DT parsing
method")
While at it also added RK8XX_DESC and RK8XX_DESC_SWITCH macros for the
regulator_desc struct initialization. This just makes the driver more compact.
Signed-off-by: Wadim Egorov <w.egorov@phytec.de>
Acked-by: Mark Brown <broonie@kernel.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
The regulators set consists of 2 BUCKs and 2 LDOs. The output
voltages are configurable and are meant to supply power to the
main processor and other components. The ramp delay is configurable
for both BUCKs.
Signed-off-by: Keerthy <j-keerthy@ti.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Just dereference match->of_node once instead of using match->of_node.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Stop the palmas regulator driver from imagining that the allocations
will always succeed. Since regulator dt nodes are optional in nature and
can be described in downstream drivers via platform data, continue to
maintain code flow as prior when of node is not found.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Converting dt to platform data logic involves picking up information
that is unique per regulator, however we can improve readability of
the code by allocating and referencing pdata->reg_init[idx] once in
the loop.
While at it, use sizeof(*pointer) when allocating pointer. This allows
for structure name changes with minimal code change.
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
Converting dt to platform data logic involves picking up information
that is unique per regulator, however we can improve readability of
the code by dereferencing ddata->palmas_matches[idx] once in the loop.
While at it fix reuse of generic palmas_matches common variable
while reporting error for a specific regulator (which may be from
65917/palmas list).
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The PWM framework has clarified the concept of reference PWM config (the
platform dependent config retrieved from the DT or the PWM lookup table)
and real PWM state.
Use pwm_get_args() when the PWM user wants to retrieve this reference
config and not the current state.
This is part of the rework allowing the PWM framework to support
hardware readout and expose real PWM state even when the PWM has just
been requested (before the user calls pwm_config/enable/disable()).
Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com>
Acked-by: Mark Brown <broonie@kernel.org>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
The enable time for buck regulators was not configured but actually is
essential: consumers, like usb3503, doing hard reset (regulator off/on)
should wait for the regulator to settle.
Configure the enable time according to datasheet.
Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The maximum supported voltage for ldo_io# is 3.3V, but on cold
boot the selector comes up at 0x1f, which maps to 3.8V.
This causes _regulator_get_voltage() to fail with -EINVAL which
causes regulator registration to fail when constrains are used:
[ 1.467788] vcc-touchscreen: failed to get the current voltage(-22)
[ 1.474209] axp20x-regulator axp20x-regulator: Failed to register ldo_io1
[ 1.483363] axp20x-regulator: probe of axp20x-regulator failed with error -22
This commits makes the axp20x regulator driver accept the 0x1f register
value, fixing this.
The datasheet does not guarantee reliable operation above 3.3V, so on
boards where this regulator is used the regulator-max-microvolt setting
must be 3.3V or less.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
LDO_REG3 descriptor is using linear_ranges.
Add and use proper ops for LDO_REG3.
Signed-off-by: Wadim Egorov <w.egorov@phytec.de>
Signed-off-by: Mark Brown <broonie@kernel.org>
The call to set_machine_constraints() in regulator_register(), will
attempt to get the voltage for the regulator. If a regulator is in
bypass will fail to get the voltage (ie. it's bypass voltage) and
hence register the regulator, because the supply for the regulator has
not been resolved yet.
To fix this, add a call to regulator_resolve_supply() before we call
set_machine_constraints(). If the call to regulator_resolve_supply()
fails, rather than returning an error at this point, allow the
registration of the regulator to continue because for some regulators
resolving the supply at this point may not be necessary and it will be
resolved later as more regulators are added. Furthermore, if the supply
is still not resolved for a bypassed regulator, this will be detected
when we attempt to get the voltage for the regulator and an error will
be propagated at this point.
If a bypassed regulator does not have a supply when we attempt to get
the voltage, rather than returing -EINVAL, return -EPROBE_DEFER instead
to allow the registration of the regulator to be deferred and tried
again later.
Please note that regulator_resolve_supply() will call
regulator_dev_lookup() which may acquire the regulator_list_mutex. To
avoid any deadlocks we cannot hold the regulator_list_mutex when calling
regulator_resolve_supply(). Therefore, rather than holding the lock
around a large portion of the registration code, just hold the lock when
aquiring any GPIOs and setting up supplies because these sections may
add entries to the regulator_map_list and regulator_ena_gpio_list,
respectively.
Signed-off-by: Jon Hunter <jonathanh@nvidia.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The minium voltage of 1800mV is a copy and paste error from the axp20x
regulator info. The correct minimum voltage for the ldo_io regulators
on the axp22x is 700mV.
Fixes: 1b82b4e4f954 ("regulator: axp20x: Add support for AXP22X regulators")
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
When commit b554e1450658 ("regulator: tps65917/palmas: Add bypass
ops for LDOs with bypass capability") introduced bypass capability
to palmas regulator, it went with the assumption that regulator
regmap helpers just check val against the bypass_mask.
Unfortunately, this ignored the explicit "on" and "off" values when
the register value is masked with bypass_mask in commit ca5d1b3524b4
("regulator: helpers: Modify helpers enabling multi-bit control").
With the recent commit dd1a571daee7 ("regulator: helpers: Ensure
bypass register field matches ON value"), this issue gets highlighted
and fails tps65917/palmas based platforms which need regulators/ldos
that have bypass capability.
Introduce the bypass_on value appropriately for tps65917/palmas
regulator.
Fixes: b554e1450658 ("regulator: tps65917/palmas: Add bypass ops for LDOs with bypass capability")
Cc: Keerthy <j-keerthy@ti.com>
Cc: Mark Brown <broonie@kernel.org>
Signed-off-by: Nishanth Menon <nm@ti.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
The current linear voltage range for the LDO4 regulator found in the APX20X
PMICs assumes that the voltage is linear between 2.5 and 3.1V.
However, the PMIC can output up to 3.3V on that regulator by skipping the
2.6V and 2.9V steps.
Fix the ranges to read and set the proper voltages.
Fixes: 13d57e64352a ("regulator: axp20x: Use linear voltage ranges for AXP20X LDO4")
Signed-off-by: Maxime Ripard <maxime.ripard@free-electrons.com>
Acked-by: Chen-Yu Tsai <wens@csie.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
After removing all uses of the range operations in a recent patch,
we get a warning about the symbol not being referenced anywhere:
drivers/regulator/rk808-regulator.c:306:29: 'rk808_reg_ops_ranges' defined but not used
This removes the now-unused structure along with the
rk808_set_suspend_voltage_range function that is only referenced from
rk808_reg_ops_ranges.
Fixes: afcd666d9db0 ("regulator: rk808: remove linear range definitions with a single range")
Signed-off-by: Arnd Bergmann <arnd@arndb.de>
Signed-off-by: Mark Brown <broonie@kernel.org>
To make the code more compat and centralized, this patch add a
unified function - regulator_ops_is_valid. So we can add
some extra checking code easily later.
Signed-off-by: WEN Pingbo <pingbo.wen@linaro.org>
Signed-off-by: Mark Brown <broonie@kernel.org>
The driver was using only linear ranges. Now we remove linear range
definitions with a single range. So we have to add an ops struct for
ranges and adjust all other ops functions accordingly.
Signed-off-by: Wadim Egorov <w.egorov@phytec.de>
Signed-off-by: Mark Brown <broonie@kernel.org>