2 Commits

Author SHA1 Message Date
Zev Weiss
08da09f028 hwmon: (pmbus) delta-ahe50dc-fan: work around hardware quirk
CLEAR_FAULTS commands can apparently sometimes trigger catastrophic
power output glitches on the ahe-50dc, so block them from being sent
at all.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Cc: stable@vger.kernel.org
Link: https://lore.kernel.org/r/20220427035109.3819-1-zev@bewilderbeest.net
Fixes: d387d88ed045 ("hwmon: (pmbus) Add Delta AHE-50DC fan control module driver")
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2022-04-27 04:52:18 -07:00
Zev Weiss
d387d88ed0 hwmon: (pmbus) Add Delta AHE-50DC fan control module driver
This device is an integrated module of the Delta AHE-50DC Open19 power
shelf.  I haven't been able to procure any proper documentation for
it, but it seems to be a (somewhat minimally) PMBus-compliant device.
It provides four fan speeds, four temperatures (three standard and one
manufacturer-specific via a virtual second page), and a vin reading.

Signed-off-by: Zev Weiss <zev@bewilderbeest.net>
Link: https://lore.kernel.org/r/20211208213703.2577-2-zev@bewilderbeest.net
Signed-off-by: Guenter Roeck <linux@roeck-us.net>
2021-12-26 15:02:06 -08:00