James Smart 036cad1f1a scsi: lpfc: fcoe: Fix link down issue after 1000+ link bounces
On FCoE adapters, when running link bounce test in a loop, initiator
failed to login with switch switch and required driver reload to
recover. Switch reached a point where all subsequent FLOGIs would be
LS_RJT'd. Further testing showed the condition to be related to not
performing FCF discovery between FLOGI's.

Fix by monitoring FLOGI failures and once a repeated error is seen
repeat FCF discovery.

Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <jsmart2021@gmail.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
2018-11-06 20:42:51 -05:00
..
2018-10-25 07:40:30 -07:00
2018-10-25 07:40:30 -07:00
2018-10-25 07:40:30 -07:00
2018-10-25 07:40:30 -07:00
2018-10-25 07:40:30 -07:00
2018-10-25 07:40:30 -07:00
2018-08-15 22:06:26 -07:00
2018-06-12 16:19:22 -07:00
2018-08-15 22:06:26 -07:00
2018-10-25 07:40:30 -07:00
2018-10-25 07:40:30 -07:00
2018-11-03 10:34:03 -07:00
2018-10-25 07:40:30 -07:00
2018-10-26 08:14:13 -07:00
2017-12-04 20:32:53 -05:00
2018-06-19 22:02:25 -04:00
2018-06-19 22:02:25 -04:00
2018-10-17 21:34:20 -04:00
2018-05-18 12:03:51 -04:00
2018-10-17 21:38:29 -04:00
2018-06-19 22:02:25 -04:00
2018-06-19 22:02:25 -04:00
2018-10-25 07:40:30 -07:00
2017-08-25 17:21:10 -04:00
2018-10-17 21:58:53 -04:00
2018-11-02 00:15:24 +09:00
2018-08-15 22:06:26 -07:00
2018-10-17 21:58:53 -04:00
2018-10-17 21:58:52 -04:00
2018-09-28 02:22:43 -04:00
2018-10-17 21:58:52 -04:00
2018-06-12 16:19:22 -07:00
2018-06-12 16:19:22 -07:00
2018-08-15 22:06:26 -07:00
2018-10-25 07:40:30 -07:00
2017-11-14 16:23:44 -08:00
2018-08-15 22:06:26 -07:00
2018-06-04 07:58:06 -07:00
2018-06-19 22:02:25 -04:00
2018-06-12 16:19:22 -07:00
2018-05-01 23:30:12 -04:00