Since commit 955fb8719efb ("thermal/intel/intel_soc_dts_iosf: Use Intel
TCC library") intel_soc_dts_iosf is reporting the wrong temperature.
The driver expects tj_max to be in milli-degrees-celcius but after
the switch to the TCC library this is now in degrees celcius so
instead of e.g. 90000 it is set to 90 causing a temperature 45
degrees below tj_max to be reported as -44910 milli-degrees
instead of as 45000 milli-degrees.
Fix this by adding back the lost factor of 1000.
Fixes: 955fb8719efb ("thermal/intel/intel_soc_dts_iosf: Use Intel TCC library")
Reported-by: Bernhard Krug <b.krug@elektronenpumpe.de>
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Acked-by: Zhang Rui <rui.zhang@intel.com>
Cc: 6.3+ <stable@vger.kernel.org> # 6.3+