Mark Brown da1c6ea6cf ASoC: Allow source specification for CODEC level sysclk
Similarly to PLLs/FLLs some modern CODECs provide selectable system clock
sources. When the clock is the clock for a DAI we do not usually need to
identify which clock is being configured so can use clk_id for the source
clock but with CODEC wide system clocks we will need to specify both the
clock being configured and the source.

Add a source argument to the CODEC driver set_sysclk() operation to
reflect this. As this operation is not as widely used as the DAI
set_sysclk() operation the change is not very invasive. We probably
ought to go and make the same alternation for DAIs at some point.

Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
2011-08-31 09:57:35 +01:00
..
2011-01-11 11:28:33 +00:00
2011-01-10 11:38:16 +00:00