Thiago Jung Bauermann 12bf85a710 powerpc/perf/hv-24x7: Fix passing of catalog version number
H_GET_24X7_CATALOG_PAGE needs to be passed the version number obtained from
the first catalog page obtained previously. This is a 64 bit number, but
create_events_from_catalog truncates it to 32-bit.

This worked on POWER8, but POWER9 actually uses the upper bits so the call
fails with H_P3 because the hypervisor doesn't recognize the version.

This patch also adds the hcall return code to the error message, which is
helpful when debugging the problem.

Fixes: 5c5cd7b50259 ("powerpc/perf/hv-24x7: parse catalog and populate sysfs with events")
Reviewed-by: Sukadev Bhattiprolu <sukadev@linux.vnet.ibm.com>
Signed-off-by: Thiago Jung Bauermann <bauerman@linux.vnet.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
2017-07-02 20:40:29 +10:00
..
2017-02-22 10:30:38 -08:00
2016-12-25 17:21:22 +01:00