[ Upstream commit 47768f372eae030db6fab5225f9504a820d2c07f ]
The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.
Add such missing properties.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
Signed-off-by: Sasha Levin <alexander.levin@microsoft.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>