Gwendal Grignou 56e4f2dda2 iio: cros_ec: Use default frequencies when EC returns invalid information
Minimal and maximal frequencies supported by a sensor is queried.
On some older machines, these frequencies are not returned properly and
the EC returns 0 instead.
When returned maximal frequency is 0, ignore the information and use
default frequencies instead.

Fixes: ae7b02ad2f ("iio: common: cros_ec_sensors: Expose cros_ec_sensors frequency range via iio sysfs")