Pali Rohár 1fe976d308 net: phy: marvell: fix detection of PHY on Topaz switches
Since commit fee2d546414d ("net: phy: marvell: mv88e6390 temperature
sensor reading"), Linux reports the temperature of Topaz hwmon as
constant -75°C.

This is because switches from the Topaz family (88E6141 / 88E6341) have
the address of the temperature sensor register different from Peridot.

This address is instead compatible with 88E1510 PHYs, as was used for
Topaz before the above mentioned commit.

Create a new mapping table between switch family and PHY ID for families
which don't have a model number. And define PHY IDs for Topaz and Peridot
families.

Create a new PHY ID and a new PHY driver for Topaz's internal PHY.
The only difference from Peridot's PHY driver is the HWMON probing
method.

Prior this change Topaz's internal PHY is detected by kernel as:

  PHY [...] driver [Marvell 88E6390] (irq=63)

And afterwards as:

  PHY [...] driver [Marvell 88E6341 Family] (irq=63)

Signed-off-by: Pali Rohár <pali@kernel.org>
BugLink: https://github.com/globalscaletechnologies/linux/issues/1
Fixes: fee2d546414d ("net: phy: marvell: mv88e6390 temperature sensor reading")
Reviewed-by: Marek Behún <kabel@kernel.org>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>