James Smart 2c3b2a8f65 scsi: lpfc: Fix PRLI handling when topology type changes
The lpfc driver does not discover a target when the topology changes
from switched-fabric to direct-connect. The target rejects the PRLI from
the initiator in direct-connect as the driver is using the old S_ID from
the switched topology.

The driver was inappropriately clearing the VP bit to register the VPI,
which is what is associated with the S_ID.

Fix by leaving the VP bit set (it was set earlier) and as the VFI is
being re-registered, set the UPDT bit.

Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com>
Signed-off-by: James Smart <james.smart@broadcom.com>
Reviewed-by: Hannes Reinecke <hare@suse.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
2018-02-12 11:43:23 -05:00
2018-02-10 13:16:35 -08:00
2018-02-09 19:32:41 -08:00
2018-01-06 10:59:44 -07:00
2018-02-06 11:32:49 -05:00
2018-02-09 19:32:41 -08:00
2017-12-13 00:00:18 +09:00
2017-11-17 17:45:29 -08:00
2018-02-10 13:16:35 -08:00
2018-02-11 15:04:29 -08:00

Linux kernel
============

This file was moved to Documentation/admin-guide/README.rst

Please notice that there are several guides for kernel developers and users.
These guides can be rendered in a number of formats, like HTML and PDF.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.
See Documentation/00-INDEX for a list of what is contained in each file.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Description
No description provided
Readme 5.7 GiB
Languages
C 97.6%
Assembly 1%
Shell 0.5%
Python 0.3%
Makefile 0.3%