Tony Lu 3b96164039 net/smc: Don't call clcsock shutdown twice when smc shutdown
[ Upstream commit bacb6c1e47 ]

When applications call shutdown() with SHUT_RDWR in userspace,
smc_close_active() calls kernel_sock_shutdown(), and it is called
twice in smc_shutdown().

This fixes this by checking sk_state before do clcsock shutdown, and
avoids missing the application's call of smc_shutdown().

Link: https://lore.kernel.org/linux-s390/1f67548e-cbf6-0dce-82b5-10288a4583bd@linux.ibm.com/
Fixes: 606a63c978 ("net/smc: Ensure the active closing peer first closes clcsock")
Signed-off-by: Tony Lu <tonylu@linux.alibaba.com>
Reviewed-by: Wen Gu <guwen@linux.alibaba.com>
Acked-by: Karsten Graul <kgraul@linux.ibm.com>
Link: https://lore.kernel.org/r/20211126024134.45693-1-tonylu@linux.alibaba.com
Signed-off-by: Jakub Kicinski <kuba@kernel.org>
Signed-off-by: Sasha Levin <sashal@kernel.org>