TI SOC EHRPWM based PWM controller
Required properties:
- compatible: Must be "ti,<soc>-ehrpwm".
for am33xx - compatible = "ti,am33xx-ehrpwm";
for da850 - compatible = "ti,da850-ehrpwm", "ti,am33xx-ehrpwm";
- #pwm-cells: should be 3. See pwm.txt in this directory for a description of
the cells format. The only third cell flag supported by this binding is
PWM_POLARITY_INVERTED.
- reg: physical base address and size of the registers map.
Optional properties:
- ti,hwmods: Name of the hwmod associated to the EHRPWM:
"ehrpwm<x>", <x> being the 0-based instance number from the HW spec
Example:
ehrpwm0: pwm@48300200 { /* EHRPWM on am33xx */
compatible = "ti,am33xx-ehrpwm";
#pwm-cells = <3>;
reg = <0x48300200 0x100>;
ti,hwmods = "ehrpwm0";
};
ehrpwm0: pwm@300000 { /* EHRPWM on da850 */
compatible = "ti,da850-ehrpwm", "ti,am33xx-ehrpwm";
#pwm-cells = <3>;
reg = <0x300000 0x2000>;
};