Hari Kanigeri 0fa035e523 omap: iommu-load cam register before flushing the entry
The flush_iotlb_page is not loading the cam register before flushing
the cam entry. This causes wrong entry to be flushed out from the TLB, and
if the entry happens to be a locked TLB entry it would lead to MMU faults.

The fix is to load the cam register with the address to be flushed before
flushing the TLB entry.

Signed-off-by: Hari Kanigeri <h-kanigeri2@ti.com>
Acked-by: Hiroshi DOYU <Hiroshi.DOYU@nokia.com>
Signed-off-by: Tony Lindgren <tony@atomide.com>