The Lex 3I380D industrial PC has 4 ethernet controllers on board which need pmc_plt_clk0 - 3 to function, add it to the critclk_systems DMI table, so that drivers/clk/x86/clk-pmc-atom.c will mark the clocks as CLK_CRITICAL and they will not get turned off. Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL") Reported-and-tested-by: Semyon Verchenko <semverchenko@factor-ts.ru> Signed-off-by: Hans de Goede <hdegoede@redhat.com> Acked-by: Andy Shevchenko <andy.shevchenko@gmail.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Linux kernel ============ There are several guides for kernel developers and users. These guides can be rendered in a number of formats, like HTML and PDF. Please read Documentation/admin-guide/README.rst first. In order to build the documentation, use ``make htmldocs`` or ``make pdfdocs``. The formatted documentation can also be read online at: https://www.kernel.org/doc/html/latest/ There are various text files in the Documentation/ subdirectory, several of them using the Restructured Text markup notation. Please read the Documentation/process/changes.rst file, as it contains the requirements for building and running the kernel, and information about the problems which may result by upgrading your kernel.