c41e024933
The pm_runtime_get_sync() internally increments the dev->power.usage_count without decrementing it, even on errors. Replace it by the new pm_runtime_resume_and_get(), introduced by: commit dd8088d5a896 ("PM: runtime: Add pm_runtime_resume_and_get to deal with usage counter") in order to properly decrement the usage counter, avoiding a potential PM usage counter leak. While here, ensure that the driver will check if PM runtime resumed at vpfe_initialize_device(). Reviewed-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org>