87f9fe8c4b
Convert the 'generic-adc-thermal' binding to DT schema format. The binding said '#thermal-sensor-cells' should be 1, but all in tree users are 0 and 1 doesn't make sense for a single channel. Drop the example's related providers and consumers of the 'generic-adc-thermal' node as the convention is to not have those in the examples. Signed-off-by: Rob Herring <robh@kernel.org> Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> Link: https://lore.kernel.org/r/20221011175235.3191509-1-robh@kernel.org Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
85 lines
2.2 KiB
YAML
85 lines
2.2 KiB
YAML
# SPDX-License-Identifier: GPL-2.0-only OR BSD-2-Clause
|
|
%YAML 1.2
|
|
---
|
|
$id: http://devicetree.org/schemas/thermal/generic-adc-thermal.yaml#
|
|
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
|
|
|
title: General Purpose Analog To Digital Converter (ADC) based thermal sensor
|
|
|
|
maintainers:
|
|
- Laxman Dewangan <ldewangan@nvidia.com>
|
|
|
|
description:
|
|
On some of platforms, thermal sensor like thermistors are connected to
|
|
one of ADC channel and sensor resistance is read via voltage across the
|
|
sensor resistor. The voltage read across the sensor is mapped to
|
|
temperature using voltage-temperature lookup table.
|
|
|
|
properties:
|
|
compatible:
|
|
const: generic-adc-thermal
|
|
|
|
'#thermal-sensor-cells':
|
|
const: 0
|
|
|
|
io-channels:
|
|
maxItems: 1
|
|
|
|
io-channel-names:
|
|
const: sensor-channel
|
|
|
|
temperature-lookup-table:
|
|
description: |
|
|
Lookup table to map the relation between ADC value and temperature.
|
|
When ADC is read, the value is looked up on the table to get the
|
|
equivalent temperature.
|
|
|
|
If not specified, driver assumes the ADC channel gives milliCelsius
|
|
directly.
|
|
$ref: /schemas/types.yaml#/definitions/int32-matrix
|
|
items:
|
|
items:
|
|
- description: Temperature in milliCelsius
|
|
- description: ADC read value
|
|
|
|
required:
|
|
- compatible
|
|
- '#thermal-sensor-cells'
|
|
- io-channels
|
|
- io-channel-names
|
|
|
|
additionalProperties: false
|
|
|
|
examples:
|
|
- |
|
|
#include <dt-bindings/thermal/thermal.h>
|
|
|
|
thermal-sensor {
|
|
compatible = "generic-adc-thermal";
|
|
#thermal-sensor-cells = <0>;
|
|
io-channels = <&ads1015 1>;
|
|
io-channel-names = "sensor-channel";
|
|
temperature-lookup-table = <
|
|
(-40000) 2578
|
|
(-39000) 2577
|
|
(-38000) 2576
|
|
(-37000) 2575
|
|
(-36000) 2574
|
|
(-35000) 2573
|
|
(-34000) 2572
|
|
(-33000) 2571
|
|
(-32000) 2569
|
|
(-31000) 2568
|
|
(-30000) 2567
|
|
/* skip */
|
|
118000 254
|
|
119000 247
|
|
120000 240
|
|
121000 233
|
|
122000 226
|
|
123000 220
|
|
124000 214
|
|
125000 208>;
|
|
};
|
|
...
|