The temperature output register of the Loongson-2K2000 is defined in the
chip configuration domain, which is different from the Loongson-2K1000,
so it can't be fallbacked.
We need to use two groups of registers to describe it: the first group
is the high and low temperature threshold setting register; the second
group is the temperature output register.
It is true that this fix will cause ABI corruption, but it is necessary
otherwise the Loongson-2K2000 temperature sensor will not work properly.
Fixes: 72684d99a854 ("thermal: dt-bindings: add loongson-2 thermal")
Cc: Yinbo Zhu <zhuyinbo@loongson.cn>
Signed-off-by: Binbin Zhou <zhoubinbin@loongson.cn>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Acked-by: Huacai Chen <chenhuacai@loongson.cn>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Link: https://lore.kernel.org/r/5198999d679f1a1c3457385acb9fadfc85da1f1e.1713837379.git.zhoubinbin@loongson.cn