In current cio2-bridge, it is using the hid name to register software node and software node will create kobject and sysfs entry according to the node name, if there are multiple sensors and VCMs which are sharing same HID name, it will cause the software nodes registration failure: sysfs: cannot create duplicate filename '/kernel/software_nodes/dw9714' ... Call Trace: software_node_register_nodes cio2_bridge_init ... kobject_add_internal failed for dw9714 with -EEXIST, don't try to register things with the same name in the same directory. One solution is appending the sensor link(Mipi Port) in SSDB as suffix of the node name to fix this problem. Signed-off-by: Bingbu Cao <bingbu.cao@intel.com> Signed-off-by: Sakari Ailus <sakari.ailus@linux.intel.com> Signed-off-by: Hans Verkuil <hverkuil-cisco@xs4all.nl>
Linux kernel ============ There are several guides for kernel developers and users. These guides can be rendered in a number of formats, like HTML and PDF. Please read Documentation/admin-guide/README.rst first. In order to build the documentation, use ``make htmldocs`` or ``make pdfdocs``. The formatted documentation can also be read online at: https://www.kernel.org/doc/html/latest/ There are various text files in the Documentation/ subdirectory, several of them using the Restructured Text markup notation. Please read the Documentation/process/changes.rst file, as it contains the requirements for building and running the kernel, and information about the problems which may result by upgrading your kernel.