IF YOU WOULD LIKE TO GET AN ACCOUNT, please write an
email to Administrator. User accounts are meant only to access repo
and report issues and/or generate pull requests.
This is a purpose-specific Git hosting for
BaseALT
projects. Thank you for your understanding!
Только зарегистрированные пользователи имеют доступ к сервису!
Для получения аккаунта, обратитесь к администратору.
In function _regulator_do_set_voltage(), old_selector gets intialised only
if (_regulator_is_enabled(rdev) && rdev->desc->ops->set_voltage_time_sel &&
rdev->desc->ops->get_voltage_sel)) is true.
Before calling set_voltage_time_sel() we checks if (old_selector >= 0) and it
will true if it got intialised properly. so we don't need to check again
_regulator_is_enabled(rdev) && rdev->desc->ops->set_voltage_time_sel before
calling set_voltage_time_sel().
Signed-off-by: Yadwinder Singh Brar <yadi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@linaro.org>