When duty-cycle is at full level (100%), the TCNTn and TCMPn registers
needs to be flushed in order to disable the signal. The PWM manual does
not say anything about this, but states that only clearing the TCON
auto-reload bit should be needed, and this seems to be true when the PWM
duty-cycle is not at full level. This can be observed on an Axis
ARTPEC-8, by running:
echo <period> > pwm/period
echo <period> > pwm/duty_cycle
echo 1 > pwm/enable
echo 0 > pwm/enable
Since the TCNTn and TCMPn registers are activated when enabling the PWM
(setting TCON auto-reload bit), and are not touched when disabling the
PWM, the double buffered auto-reload function seems to be still active.
Lowering duty-cycle, and restoring it again in between the enabling and
disabling, makes the disable work since it triggers a reload of the
TCNTn and TCMPn registers.
Fix this by securing a reload of the TCNTn and TCMPn registers when
disabling the PWM and having a full duty-cycle.
Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>