The dual tachometer feature is implemented in hardware with a TACHSEL
input to indicate the rotor under measurement, and exposed on the device
by extending the READ_FAN_SPEED_1 word with two extra bytes*. The need
to read the non-standard four-byte response leads to a cut-down
implementation of i2c_smbus_xfer_emulated() included in the driver.
Further, to expose the second rotor tachometer value to userspace the
values are exposed through virtual pages. We re-route accesses to
FAN_CONFIG_1_2 and READ_FAN_SPEED_1 on pages 23-28 (not defined by the
hardware) to the same registers on pages 0-5, and with the latter command
we extract the value from the second word of the four-byte response.
* The documentation recommends the slower rotor be associated with
TACHSEL=0, which corresponds to the first word of the response. The
TACHSEL=0 measurement is used by the controller's closed-loop fan
management to judge target fan rate.
Signed-off-by: Andrew Jeffery <andrew@aj.id.au>
Signed-off-by: Guenter Roeck <linux@roeck-us.net>