According to sysfs-bus-iio documentation the unit for accelerometer
values after applying scale/offset should be m/s^2, not g, which explains
why the scale values for the other variants in bmc150-accel do not match
exactly the values given in the datasheet.
To get the correct values, we need to multiply the BMA222 scale values
by g = 9.80665 m/s^2.
Fixes: a1a210bf29a1 ("iio: accel: bmc150-accel: Add support for BMA222")
Reviewed-by: Linus Walleij <linus.walleij@linaro.org>
Signed-off-by: Stephan Gerhold <stephan@gerhold.net>
Link: https://lore.kernel.org/r/20210611080903.14384-2-stephan@gerhold.net
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>