6fe4dfd041
In current code, the tick count value programmed to the hardware is always decremented by one. This is reasonable for periodic mode, since there is one extra tick between 0 and COUNT (after reloading), but it makes oneshot events happen 1 tick earlier than requested, because the interrupt is triggered on transition from 1 to 0. This patch removes the decrementation from PWM channel setup code and moves it instead to periodic timer setup, to make both periodic and oneshot modes work correctly. Signed-off-by: Tomasz Figa <t.figa@samsung.com> Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com> Reviewed-by: Arnd Bergmann <arnd@arndb.de> Acked-by: Kukjin Kim <kgene.kim@samsung.com> Signed-off-by: Olof Johansson <olof@lixom.net>