Qipan Li 7282cec903 serial: sirf: transfer more bytes once to decrease interrupts
the current codes send 1 bytes, then after getting TX done interrupt,
send subsequent bytes. it causes redundant interrupts.
for example, if we have 3 bytes in TX buffer, the TX flow is:
1. send 1 byte
2. get TX down interrupt
3. send the left 2 bytes
4. get TX down interrupt

this patch moves to send more bytes and decrease interrupts, the new
flow is:
1. send 3 bytes
2. get TX down interrupt

Signed-off-by: Qipan Li <Qipan.Li@csr.com>
Signed-off-by: Barry Song <Baohua.Song@csr.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>