Fabrice Gasnier
7531cf59bf
iio: adc: stm32-dfsdm: fix successive oversampling settings
When doing successive oversampling settings, it may fail to update filter parameters silently: - First time oversampling is being set, it will be successful, as fl->res is 0 initially. - Next attempts with various oversamp value may return 0 (success), but keep previous filter parameters, due to 'res' never reaches above or equal current 'fl->res'. This is particularly true when setting sampling frequency (that relies on oversamp). Typical failure without error: - run 1st test @16kHz samp freq will succeed - run new test @8kHz will succeed as well - run new test @16kHz (again): sample rate will remain 8kHz without error Fixes: e2e6771c6462 ("IIO: ADC: add STM32 DFSDM sigma delta ADC support") Signed-off-by: Fabrice Gasnier <fabrice.gasnier@st.com> Acked-by: Arnaud Pouliquen <arnaud.pouliquen@st.com> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
…
Linux kernel ============ This file was moved to Documentation/admin-guide/README.rst Please notice that there are several guides for kernel developers and users. These guides can be rendered in a number of formats, like HTML and PDF. In order to build the documentation, use ``make htmldocs`` or ``make pdfdocs``. There are various text files in the Documentation/ subdirectory, several of them using the Restructured Text markup notation. See Documentation/00-INDEX for a list of what is contained in each file. Please read the Documentation/process/changes.rst file, as it contains the requirements for building and running the kernel, and information about the problems which may result by upgrading your kernel.
Description
Languages
C
97.6%
Assembly
1%
Shell
0.5%
Python
0.3%
Makefile
0.3%