Hans de Goede 77c2a3097d power: supply: bq24190: Call power_supply_changed() after updating input current
The bq24192 model relies on external charger-type detection and once
that is done the bq24190_charger code will update the input current.

In this case, when the initial power_supply_changed() call is made
from the interrupt handler, the input settings are 5V/0.5A which
on many devices is not enough power to charge (while the device is on).

On many devices the fuel-gauge relies in its external_power_changed
callback to timely signal userspace about charging <-> discharging
status changes. Add a power_supply_changed() call after updating
the input current. This allows the fuel-gauge driver to timely recheck
if the battery is charging after the new input current has been applied
and then it can immediately notify userspace about this.

Fixes: 18f8e6f695ac ("power: supply: bq24190_charger: Get input_current_limit from our supplier")
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
2023-05-08 15:29:12 +02:00
..
2023-02-27 10:04:49 -08:00
2023-02-27 10:04:49 -08:00