Ryan Lee 7a0d884986
ASoC: max98373: Added controls for autorestart config
3 new controls are added.
"OVC Autorestart Switch" : controls whether or not the speaker amplifier
automatically re-enables after an overcurrent fault condition.
"THERM Autorestart Switch" : controls whether or not the device
automatically resumes playback when the die temperature recovers from
thermal shutdown.
"CMON Autorestart Switch" : controls whether or not the device
automatically resumes playback when the clock returns after stopping.

Above Auto Restart functions are enabled by default.

Signed-off-by: Ryan Lee <ryans.lee@maximintegrated.com>
Link: https://lore.kernel.org/r/20210325033555.29377-3-ryans.lee@maximintegrated.com
Signed-off-by: Mark Brown <broonie@kernel.org>
2021-03-25 13:58:57 +00:00
..
2020-07-03 17:33:46 +01:00
2021-03-10 13:08:46 +00:00