When the network interface goes down while a scan request is still pending that can't be stopped due to firmware hickups, wcn->scan_req remains set, even though the hardware is deinitialized. This results in -EBUSY for all scan requests after the interface was brought up again. Fix this by explicitly completing pending scan requests in wcn36xx_stop(). Signed-off-by: Daniel Mack <daniel@zonque.org> Signed-off-by: Kalle Valo <kvalo@codeaurora.org>