H Hartley Sweeten 8447e4781f spi: spi-ep93xx: use 32-bit read/write for all registers
All the EP93xx SSP registers are 32-bit. Since most of the upper bits
are unused, this driver tries to be tricky and uses 8 or 16-bit I/O to
access the registers. This really just adds a bit of confusion.

Simplify the I/O by using 32-bit read/write's for all of the registers.

Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
[chris: use u32 instead of unsigned int]
Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz>
Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com>
Signed-off-by: Mark Brown <broonie@kernel.org>